    Vaillant 637 Ecotec plus - air bubbles in system

    thank you for the replies. iateyoubutler - I put in a new boiler 2 years ago and have been having this issue. Went from vented to unvented and renewed mains pipe into house. Put in 3 new vertical radiators as a part of an extension on the first floor. Plumber originally thought boiler was...
  2. R

    Vaillant 637 Ecotec plus - air bubbles in system

    General question to Vaillant engineers - is it possible for the boiler to create air bubbles in a sealed system. Reason I ask is i'm bleeding air from the same radiator every night for the last 2 weeks. It's a new vertical radiator on the floor directly above boiler. Wondering if installing...
  3. R

    Banging Central Heating pipes

    Ticking and clicking is what I would normally expect - had it with last system but was not a big deal. My issue is definitely banging - it's so loud in the morning have to switch offending radiator off. Still hear some banging but not so bad. Will try placing screwdriver against valve when I...
  4. R

    Banging Central Heating pipes

    Madrab - All the TRVs are bi-directional- was first thing I checked Mottie - Spirovent deaerator does look interesting
  5. R

    Banging Central Heating pipes

    Thank you for your reply. Yes has thermostatic valves. I have already tried that but made no difference.
  6. R

    Banging Central Heating pipes

    Before I ask my question some background on my heating system. Installed Vaillant 637 Ecotec boiler two years ago when I had my garage converted into a room. Had underfloor heating installed into garage and a new vertical radiator installed in room above. Went from a vented to unvented system...
  7. R

    Vaillant Ecotec plus 637 - Anti cycling

    Set D.14 to 100% and the temperature difference is 5C after 5 mins. Goes into pump over run after about 5 mins in burner mode. Room thermostat has been reached and been steady for several hours
  8. R

    Vaillant Ecotec plus 637 - Anti cycling

    The cylinder is set between 50-55 C. The 637 was fitted in 2019. D19 is the pump operating mode and is set to 2 - stage pump - auto. Setting it to 3 sets operating mode always to stage pump. What does always setting to stage pump (3) do versus auto (2)?
  9. R

    Vaillant Ecotec plus 637 - Anti cycling

    Thanks - extending the pump over-run slightly was exactly what I ended up doing to avoid sitting in anti-cycling. The pump over run is set at 7 mins. D.0 is set at 15KW and everything works well now. Only thing I'm trying to understand is why once target flow temperature is reached...
  10. R

    Vaillant Ecotec plus 637 - Anti cycling

    Reduced power to 13KW and anticycling has disappeared. Radiators working well. Have a more general question about boiler cycling. If the weather outside is really cold (say -30C) and my house has lots of heat loss, the boiler will have constant demand for heat. Does that mean that if the...
  11. R

    Vaillant Ecotec plus 637 - Anti cycling

    Power reduced to 15kw and still getting anti-cycling for a few minutes at the end of each cycle. Should I reduce power further?
  12. R

    Vaillant Ecotec plus 637 - Anti cycling

    You are right - I don't use the radiators all the time particularly with insulation being so good in some rooms that some radiators not switched on next day. I will take heating load down to 15KW. I also saw a max anticycling time of 20 mins (default setting). Should I leave that alone? I saw a...
  13. R

    Vaillant Ecotec plus 637 - Anti cycling

    Should I leave heating set up as it is or should I make any adjustments?
  14. R

    Vaillant Ecotec plus 637 - Anti cycling

    I have 15 radiators and the floor area of the house about 1800 square feet. Had the boiler changed about 2 years ago. Added an extension with two extra radiators and the boiler went from 28KW and 37KW. Installer insisted it was justified although I do agree with you that it is oversized as I...
  15. R

    Vaillant Ecotec plus 637 - Anti cycling

    Boiler goes into anti-cycling mode for a few minutes at the end of each cycle after pump over-run. Does anyone know if it's normal or whether I need to make adjustments to my heating set up
  16. R

    Vaillant Ecotec plus 637 - Pump Over run

    Looking at other posts online it seems the 637 ecotec is a powerful boiler that does have problems losing the extra heat. The banging when boiler is in pump overrun seems to be loudest in the two radiators without TRVs ( bathroom and hallway). I've lowered the power setting of the boiler to...
  17. R

    Vaillant Ecotec plus 637 - Pump Over run

    Are there any settings in the boiler that need to be looked at?
  18. R

    Vaillant Ecotec plus 637 - Pump Over run

    Thanks Harry Bloomfield - so I assume heat is lost through the radiators. Mottie - how do I check if the auto by-pass is set up correctly?