Search results

  1. A

    Nozzle change on HRM Wallstar 12 14

    Wallstars with intermittent lock outs can even test experienced engineers. Are there any bubbles in the clear flexi oil line or do you have a static one at the top of the curve? If you have run out of oil make sure the in line filters are clean.
  2. A

    iPhone Voice Problem

    Apparrantly I sound like I'm underwater when I answer my IPhone. Is my phone fooked or is this a common prob?
  3. A

    grant vortex pro condensing boiler cutting out

    Solenoid for RDB's should be 100 ohms (plus or minus 5 per cent). Your resistance reading might be fine when boiler is cold but sometimes the solenoid goes open circuit when heated, ie. during a heating cycle. I have found solenoids failing as quickly as 2 minutes into a heating cycle...
  4. A

    Issuing Gas Safety Certificate & requirements

    Blimey it seems that you are not suited to being involved in the property rental game! What about racehorses, spread-betting or everything on black at the Casino! Some of my customers rent properties but they are difinitely not ripped off!
  5. A

    Burner LOA24.171B27 not firing...

    Hi. Bit more information required. Firstly, why was a new pump fitted and who did it? Were there problems with the boiler before the pump was fitted?
  6. A

    Wallstar cutout - can wind cause it?

    OP are you really in your eighties? I have to ask as most eighty something's I know do not use the term "guy"? I stand to be corrected.....
  7. Untitled

    Untitled

  8. Landis

    Landis

  9. A

    Why are some plumbers such a let down ?

    Don't tell PVM .....
  10. A

    Why are some plumbers such a let down ?

    Male and No! My hobbies are football, cricket and Rugby. I support Spurs and I have hazel eyes. I like a bit of cooking and hate cats. GSOH. Please reply PO Box 3456
  11. A

    Why are some plumbers such a let down ?

    Hold on I'll ask the Mrs.....
  12. A

    Why are some plumbers such a let down ?

    I have to admit that I have been sniggering about this for most of the day.... Thanks Marb for the original, and I suspect well-intentioned, post. You have inadvertently provided some much needed entertainment for me....
  13. A

    Why are some plumbers such a let down ?

    "One house I used to go to I don't think the cats knew exactly where their a**e's were, the tray was surrounded by turds and hardly any in the tray, it was almost like a competition to see which cat could get it's turd the nearest to the tray without actually getting it in, bit like bowls, only...
  14. A

    pressure keeps dropping in combi boiler

    Sorry BM you must have clicked just before me!
  15. A

    pressure keeps dropping in combi boiler

    Hi. How often are you repressurising? Are there any obvious signs of a leak in boiler and/ or on your rads/ pipe work? If not then check that your expansion vessel has not lost its charge. If it has then it will have to be repressurised and/or replaced.
  16. A

    Baxi Solo 2 50pf ignition

    What you are doing, by your own admission, is illegal.
  17. A

    Baxi Solo 2 50pf ignition

    Hey OP how many boilers have you got. You appear to have also "worked" on a Vokera Linea and a Potty Profile 50? Unless of course you live in a large property/have a second home/swimming pool etc?
  18. A

    Boiler pressure keeps rising.

    Alex could you run through how you recharged the expansion vessel?
  19. A

    Boiler pressure keeps rising.

    Is water discharging from the prv discharge pipe outside?
  20. A

    Why does my combi boiler keep gaining pressure?

    Have you tried disconnecting filling loop? If after disconnecting the pressure still rises then might be a holed plate heat exchanger
Back