  1. G

    installing low voltage room stat

    Low voltage lighting flex will be ok
  2. G

    Glowworm Micron Wont Fire Up....?

    This indicates ignition lock out could be gas related or the ign. lead/electrode as previousely mentioned. Can be mistaken for a slow flahing light which could be pcb fault
  3. G

    Glowworm Ultimate 50FF & pilot light

    The pcb has some neons on it, 4 i think they light at different sequances. Should tell you how far up the ignition it is going.I think there are two fuses on the board one is for the pump not sure which one, s/be a wiring diagram on the boiler case.If the pilot is lighting and it continues to...
  4. G

    installing low voltage room stat

    You remove the link blue wire i think do not put 240v on this or you will blow the pcb.1normally fit the honeywell programmable stat CM67 with optional auto time module.The stat automatically adjusts summertime
  5. G

    Glowworm Ultimate 50FF & pilot light

    Check the ignition lead it could be shorting on the case check connection to pcb
  6. G

    vaiilant combi

    dont reconize that fascia are you sure it is a vaillant? how old is it ?
  7. G

    Glowworm Micron Wont Fire Up....?

    If it is just the reset flashing and no other light on this indicates a pcb fault. if the other light is flashing is it fast or slow to determine the fault.The original pcb on the micron had orange light and would attempt one ignition the later boards should attempt 3 times.There is not a pilot...
  8. G

    Glowworm Ultimate 50FF & pilot light

    Does the pilot go out,if it stays on all the time gas valve faulty.Maybe trying to ignite when permantley on
  9. G

    saunier duval lockout problem

    If you have worked on a glow-worm compact 100e then you have worked on a sd 30e same boiler different badge. The pump maybe opposite side if the filter is in situ it will be under pump and can be tricky to get at depending how much working space is available. tHE MODERN sauniers are okay to work...
  10. G

    Condensing boiler pipe lagging

    Copper pipe is a no no as it will corrode due to the acid nature of the condesate hence the use of plastic non corrosive pipe get them back and get it changed
  11. G

    saunier duval lockout problem

    I think there is a filter beneath the pump this could be causing the boiler to over heat if it is blocked.Try the pressure diff pin see if is moving in and out freely, this can cause lock out. Oyher possibilities are o/heat stat faulty plus the c/h and dhw thermisters,ign. rate, pump sticking...
  12. G

    New boiler

    I said the ecomax pro is a glow-worm hxi apart from the display.The last time i opened an ecomax 6/800series the heat exc. and flue adaptor were the same.The ecotec was changed in that the h/exch now incorporates the adaptor flue adaptor as a wrap round version.There is a saunier on the market...
  13. G

    New boiler

    The Ecomax Pro is not saunier in disguise infact the glow-worm hxi has the same parts except for the display card.The h/exch is as the veissmann,baxi,glow-worm etc.Very reliable boiler, now all the early problems have been sorted.Provided it is installed correctly no problems,i install them...
  14. G

    icon combi boiler

    Best to take the whole lot out the divertor has a push fit into the dhw h/exch so that has to come off. Will need to replace all the washers as it will leak.Worse boiler they make to work on
  15. G

    Glow worm combi boiler hasn't worked since new

    F9 on some boilers is a global fault i.e you need to have a external diagnostic machine plugged in to see what is going on.It sounds like a blocked secondary heat exchanger(dhw}.It is normal in this situation for the central heating to appear to be working, as the boiler dumps heat into the...
  16. G

    Glowworm Energysaver 60

    Yes it has ,it is situated above the top heat exchanger sometimes if the fan is leaking condenate it blows the o/heat stat.
  17. G

    Glowworm Energysaver 60

    Yes it has ,it is situated above the top heat exchanger sometimes if the fan is leaking condenate it blows the o/heat stat.
  18. G

    Vaillant ecoMax pro 28E

    The ecomax pro 28e is the HXI in disguise the only boiler they do for a normal vented system
  19. G

    Vaillant ecoMax pro 28E

    Apart from the display and pcb it is a glow-worm HXI and suprise it is cheaper.No serious problems encountered just the odd noisey one on start-up can be cured by de-ratring fan speed.
  20. G

    New Glow worm Flexicom Anyopne used and or have comments?

    Have fitted 4 now, only problem is two had explosive ign.Turns out problem with electrode arcing on h/exch. glow-worm fitted modified electrode no probs since.Also there is polystyrene packer fitted on front case which can lead to noise from fan vibrating to casing scapping this off will cure...