  1. G

    Vaillant turbomax plus - S33 code

    Have had this acouple of times, on the aqua plus as well in my case changing the fan cured the problem it was not modulating properly but these are only fitted to the larger models so may not apply to you.
  2. G

    Gloworm Swiftflow Honeywell

    On these boilers fan runs constant to provide air for the pilot to burn some have air pressure switch, some do not normally it is the thermo couple or/and the o/heat stat weak.Although had one last week the meter gov. was gone it was ok to light pilot but soon as burner lit w/p at meter dropped...
  3. G

    CH switching off after couple of minutes

    Did you drain out of the p.r.v if you did look outside and see if the pipe is dripping could be the p.r.v letting-bye
  4. G

    Buzzing boiler, think it's gonna cost me.

    Have known make a noise when to much inhibitor in system they swell up and spin and can make a racket i generally replace them after draining system and refilling with less inhibitor usually cures noise
  5. G

    Glow worm 30 cxi

    actuator is the black motor clipped on to the divertor valve which drives a spring loaded pin in to divert flow to the c/h you can unclip it and see if it drives in or out.
  6. G

    Glow worm 30 cxi

    If it is a new install check the blue wire on the low voltage is disconnected.If it is not it will by-pass the controls and remain on.it could be a faulty timer, or the 240 volt option board playing up. Have had some with the orange link in the p.c.b left in this will also by-pass all the ext...
  7. G

    JAGUAR 28KW NOT IGNITING FROM COLD F1 FAULT CODE

    I do evidently you do not fella (for instance is a gas valve i have taken apart fully modulating ) say no more Agile said it all.And this is really the end of.
  8. G

    FULLY MODULATING COMBINATION BOILER ?

    So you think it is okay to advise a diyer to take a gas valve apart if that is the general concencious ,i personally do not .As for the name calling fair enough i apologise. As you said you are no expert and i do not rip people off nuff said
  9. G

    FULLY MODULATING COMBINATION BOILER ?

    So you think it is okay to advise a diyer to take a gas valve apart if that is the general concencious ,i personally do not .As for the name calling fair enough i apologise. As you said you are no expert and i do not rip people off nuff said
  10. G

    FULLY MODULATING COMBINATION BOILER ?

    This **** just advised a novice to take a gas valve apart :roll:
  11. G

    JAGUAR 28KW NOT IGNITING FROM COLD F1 FAULT CODE

    If you think it is okay to mess with gas so be it, but do not imply it is okay for others to do so. if you you got ripped off as you say then tough, for every cowboy there are ten good corgis ,as for the competent diy advocates if you are so competent why do you ask for advice on this site it...
  12. G

    JAGUAR 28KW NOT IGNITING FROM COLD F1 FAULT CODE

    probably is gas valve with second post original post said no spark was trying to accommodate both posts
  13. G

    JAGUAR 28KW NOT IGNITING FROM COLD F1 FAULT CODE

    If you phone glowworm they will send you a manual if you are certain it was not sparking then it will not just be the gas valve i beleive glowworm do a fixed fee repair try them
  14. G

    JAGUAR 28KW NOT IGNITING FROM COLD F1 FAULT CODE

    F1 no gas or faulty gas valve cvi unit could be faulty maybe air pressure switch another possibility ign. lead defect
  15. G

    No hot water kitchen sink and bathroom sink

    Firstly have you got a combi boiler if so which model i had a compact doing what you describe it was the diaphrham split would work on the bath but not the basins because the pressures were greater on 15mm pipe work
  16. G

    No CH from Glow-worm combi

    open pump vent see if it is spinning if not try to free it other possibility c/h thermistor fault check aav is open could be air lock
  17. G

    No CH from Glow-worm combi

    is the central heating switch on the boiler on located above the gas valve .Do not think boiler has divertor valve has bi-thermic h/exch relies on pump for c/h.
  18. G

    Boiler in conservatory

    So the information printed in junes edition of gas installer is wrong regarding relllocation and installation of used appliances.Needs to be adressed or could cause some issues maybe even fines.
  19. G

    Boiler in conservatory

    You will need to notify corgi if you move the boiler as per june edition of gas installer .They wont know so what the hell forget it
  20. G

    Boiler in conservatory

    I misread regs you can relocate boiler but you have to do a gwn and treat it as a new installation and get a exemption code. Might as well fit a steamer by the time you re-run pipe work and flue etc