  1. S

    Ducting in CLS 63mm studword

    The problem with those lovely warm condensing dryers is they still kick out moisture. Ours despite being 1year old Samsung Heatpump we now have mould forming on the coving directly above Dryer. Hence im trading it for a vented. Im guessing re studwork if i cut the slow really low it won't...
  2. S

    Ducting in CLS 63mm studword

    I need to vent out the tumble dryer along a 2m stud wall to external. The wall is constructed of 63mm CLS timber. I was looking at cutting through the uprights with 54mm venting am i literally cutting it too thin as i guess im going to end up with a max of 4mm walls ifi cut the slots dead...
  3. S

    Screed quotes

    I've been quoted £2100 to lay celotex and membrane (supplied by us) and 75mm screed supplied by company over 45m2. Any rough idea what I should be paying per m2 on 75mm screed plus labour over block n beam floor? I'm so fed up with such wild quotes from every trade.
  4. S

    Sewage tank install.

    Thanks Hugh no traffic here it's off the driveway so safe from that. Also the cable will shortly be properly glanded and either swa or whatever armour protection needed back to the house.
  5. S

    Sewage tank install.

    Here is an attached picture they said due to the pipe exit height it had to be dig in beneath ground level. I already have standing water forming around it. Will I need some sort of brick surround to stop water getting in?
  6. S

    Sewage tank install.

    Ive just had a small sewage tank installed externally to house(610x635mm)to pump the waste from our utility room up the driveway to the existing sewage outlet. The installers seemed to be in a hurry which concerned me, i did check with the pump suppliers who said it should be dropped in a wet...
  7. S

    Pumping station advice

    Hi i am looking at a pump station for our extension to pump up to our sewage pipe about 3metres away(very slight incline). The extension has a guest toilet, washing machine and sink (utility) I was looking at this ...
  8. S

    Warm roof concern

    Tape it no did they fck... well it seems after asking the building control again after asking them 'what would you do if this was YOUR house' we had the obvious answer of make them do it again properly. Hopefully that will happen this week sometime. Thankyou for your input here.
  9. S

    Warm roof concern

    Our building control officer claimed 'it should be ok' as the foiled backed pir foam acts as a VCL?! I feel we can trust noone, apart from this new roofer, is that bs?
  10. S

    Warm roof concern

    Thanks Harry, indeed a good question, does show their lack of competency. So all has to come off and be replaced i guess?
  11. S

    Warm roof concern

    We had some concerns with our roofers and quality of work so called out a reputable roofer to check out the work on our warm flat roof with the intention to possibly take over the job. He immediately noticed breathable roofing membrane had been used instead of a VCL (vapour control layer). I...
  12. S

    Plumbing in cistern

    Thanks for your thoughts if i was going to put it further away i think i would have considered a braided loop instead of multiple elbows etc.
  13. S

    Plumbing in cistern

    I am about to plumb in the toilet cistern and would appreciate some photos of a tidy job you've done or other examples. I looked at a braided loop maybe with isolater valve or similar. I want it to look as neat as possible as it will be visible as the door is to the left of toilet. Here is an...
  14. S

    Samsung heat pump dryer drum seized?

    Just to update here for anyone wondering if i fixed it. I took the back panel off which covers the drum drivebelt and exposes the fan bottom left driven by the main motor. I turned that by hand as it seemed to be seized, this free'd up the rotation of the drum. Refitted it all fire up the...
  15. S

    EPDM checks

    HI i have a roofer over today and would appreciate a few pieces of advice as im keen to see it's done properly (witnessed a few issues that have concerned me). The install is on a flat roof with parapet wall. Should the perimeter of the roof (100mm edge?) be bonded with contact adhesive over...
  16. S

    Blocking gap between warm and cold roof.

    How do we go about blocking off this area between old roof space cold roof and new flat roof warm roof. Photo attached you can see the old roof and gaps linking cold roof. Thanks.
  17. S

    Samsung heat pump dryer drum seized?

    Our heat pump dryer is only a few years old. However this morning I heard an ominous grumbling sound like a drive belt jumping and the drum had stopped. I tried to start it again and could just hear a humming I guess of motor trying to turn. Removed all laundry and the drum feels really stiff...
  18. S

    Paslode not firing im350

    I cleaned out the cylinder head area especially round the igniter, the main piston area and checked all o-rings. Re applied the paslode oil to the bore and orings, with a fresh paslode gas cylinder works like a charm again thanks.
  19. S

    Paslode not firing im350

    Oh refitted canister worked for a moment same issue.
  20. S

    Paslode not firing im350

    Ok always been good to me but not used for about 6 months. Put fresh canister in checked chute but won't fire. Fan runs and smells a bit of gas after. Light flashes green and about every five secs a red light flashes in-between any ideas? Tia