    Baxi 105e - Luke warm DHW continues....

    He has already changed this... I would be checking that you are getting the correct gas pressures... might be more than you want to tackle tho! If the tap is flow at more than say 10 ltr/min then it may be too much but from a kitchen tap this is usually not the case...normally the bath...
  2. S

    HELP no HEATING -WORCESTER 280-new diverter valve problem

    No...no no no!!!! I said 1 - 1.5!!!!! 2 is ok...but no more when its cold Try the red reset!
  3. S

    Vaillant vs. Baxi

    north of the border it would be a vokera for some reason!
  4. S

    HELP no HEATING -WORCESTER 280-new diverter valve problem

    What is the pressure guage reading on the front of the boiler, it may have ran dry and overheated. The pressure should read 1 - 1.5, if its not fill it upto this level. There is a red overheat reset on the top of the boiler, reset this and away you go.
  5. S

    Boiler won't come on unless triggerd by cylinder thermostat

    end switch on the 3 port valve is faulty, or the valve is jammed in mid position not allowing the end switch to be made. remove the head of the valve and check the little spindle on the body is moving freely. If it is replace the valve head. Good luck.
  6. S

    worcester bosch 24cdi filler loop leak

    Sure you have the correct size o ring, there are loads of different sized o rings on this boiler.
  7. S

    Adding a rad without draining down

    You sound like you have the correct idea, its a sealed system so not that much water will come out after you have cut the pipe, just have lots of olds towels near by and a couple of buckets. no harm in squirting in a new bottle of inhibitor to the system, before you fill back up, maybe only...
  8. S

    Potterton suprima 50 green LED flash thermistor fault

    Only if its the PCB thats the fault.... can be lost of other things too ie Gas valve, APS, spark electrode or the lead.
  9. S

    Gloworm Micron 50FF Reset

    Was the electrode checked as they can be wrongly positioned or cracked which could give a weak or no spark.
  10. S

    Gloworm Micron 50FF Reset

    There is a modified PCB and ignition electrode for this boiler available as they had problems with lockout. Pump sticking intermittanly would be the next shout...easlily changed and a lot cheaper than a new PCB.
  11. S

    Potterton suprima 50 green LED flash thermistor fault

    Is the pump working properly...could be running very sluggishly and not getting the water away from the boiler quick enough... or there could be a restriction some place... Which PCB do you have...does it have a square reset or a round one?? 1 led or 2??
  12. S

    1000ltrs of oil in 2 months???????????

    Check out www.boilerjuice.com for a good search tool for the cheepest suppliers!
  13. S

    Megaflow and Potterton Prima Boiler grief.

    The boiler is getting too hot for some reason!, it could be a faulty boiler thermostat or the overheat cut out or the pump overrun stat... there are 3 stats on this boiler and I would personally change all 3. It is also worth checking that there is not a jammed zone valve which is keeping...
  14. S

    Maxol microturbo 40

    Dirty injector on the top??
  15. S

    Boiler goes "BOOM"

    The boiler may not have been commissioned properly and the min/max CO2 readings may be out causing problems, or a faulty component as suggested alternativley What size is the gas pipe to the boiler and how far does it run?? May be undersized???
  16. S

    BAXI Barcelona woes

    Sticky pump first thing in the morning?? Gas valve?? could be iffy?? Had one go faulty and it was a swine to light but once it got going is was ok.... they are factory set so you cannot adjust the min and max settings like other boilers.
  17. S

    potterton performa 24

    The mesh filter is in the CH return isolation valve, there is a cap facing you as you look at it, or the filling loop pipe goes onto it if thats where the installers have fitted it. once cap/filling loop is removed the filter is a mesh tube that pulls out for cleaning, its not like the...
  18. S

    Central heating power flush, boiler now cutting out

    Have the cold feed and expansion pipes been cut out to check for blockages there?? Use a magnet where they T into the flow pipe?? A powerflush machine will never shift a proper blockage no matter what chemical is used..the blockage needs to be cut out and pipework cleaned or replaced.... and...
  19. S

    baxi

    3/4 of the way up...or however hot you want your rad temp to the touch to be.
  20. S

    Potterton Suprima 60L sequence onans off??