Search results

  1. S

    Baxi Bermuda inset 2 50/4E Banging loft pipes and hot rads

    Another suggestion is whats the Pump like?? It might be jamming intermittantly??
  2. S

    Baxi Bermuda inset 2 50/4E Banging loft pipes and hot rads

    What is the Thermostat set to on the front of the back boiler unit?? I usually leave them at 3 as this is usually ample Has the boiler thermostat Phial been properly inserted onto the Backboiler unit would be my next question? Following this do you have Thermostats on ALL of your...
  3. S

    Potterton Puma 80 water dripping from CH Temperature Sensor

    Remember and let the pressure off the system befre you go unscrewing anything or you will end up with a unwanted shower!! :-D
  4. S

    Another Viessmann 100 problem

    Why not range rate it down... tells you how to reduce the CH rate if there is a small load on the system in the Manf instructions using POT A on the PCB. If its 30kw firing at full power with 4 rads it will get up to heat super fast! Make sure the rad valves are open for max flow through...
  5. S

    Potterton Puma 80 water dripping from CH Temperature Sensor

    or if you really want to save the pounds then.... PTFE tape on the threads of the sensor and screw it back in... not pretty but it works!
  6. S

    common problem?

    In the wiring centre 2 is a neutral 4 is the switched live from the prog going to the common on the room stat 5 is the switched live from the room stat to the mid pos valve. R/S W/C 2 > 4 3 > 5 depending on the room stat you may also need to link up the neutral wire
  7. S

    heatline s30

    You are almost correct Tony!! According to the Manf inst there is a pot for ignition BP... number 4 though!! :-D Pot 3 is for the CH range rating. According to the MI's pot 4 is factory set and it does not actually give a valve to set it to?? After reading the MI's I would be checking...
  8. S

    Vokera Linea 24 rattle noise

    Nickso is spot on there, the diverter produces more squeels that rattles and as for the new one rattling, thats why unless the customer reports the noise I leave well alone and never open my mouth!! :-D
  9. S

    Combined heat and vent pipe location

    Yes which ever is produced...I always get confused between the two!! :-D
  10. S

    heatline s30

    depends on how thorough your engineer was?? And if he thought of that. The other thing I would be looking at, is there a flue restrictor ring which restrics the air flow into the boiler.... might be muffling its self, or is there something in the flue???
  11. S

    Replacing Gas Fire with Electric?

    If you have a powercut, you can usually use a gas fire as long as there are no electrical controls..... how often do you have a 'Gas-cut'?? BG will do a disconnect appliance job for maybe £80-£100 if its not too involved otherwise a quote could be given if there is more work than a bit of...
  12. S

    heatline s30

    This should read....some of BG are bad at diagnosis! The Technical Support manager should be invovlved in any job that has had this many visits, he may be a bit more experianced in tricky faults?? Dont think there is a BP ignition setting on the PCB on any of the baxi's?? Is the...
  13. S

    Combined heat and vent pipe location

    It could be nitrogen being produce by corrosion, Is there plenty inhibitor in the system??
  14. S

    WORCESTER HIGHFLOW3.5 BFSS FLOOR MOUNTED

    Blow off the pressure and get a foot pump onto the expansion vessle. should be 0.75 - 1 bar. After this check that the PRV is not passing. Maybe you still have a little leak some place that is evaporating with the heat??
  15. S

    Worcester Bosch 12Ri Question?

    I would say this might be slightly undersized, you would be better to future proof it and fit an 18 - 20kw model then if you upgrade rads or add extra it will still be ok.
  16. S

    15mm or 22mm pipe

    as you said...22mm most of the way where there are multiple service needs, once down to one supply you could run 15mm. and plenty pipe clips!!
  17. S

    Potterton Performa 24 - replacing DHW HEX

    for that price they may be fitting a magnaclean aswell as the heat exchanger to help prevent further carp getting back to the boiler. Phone the call centre and ask for a 2nd opinion.
  18. S

    Vokera Compact central heating problem

    is the time clock turned on and the room thermostat up??
  19. S

    ideal isar m30100 problem help pls!

    Make sure the connector if fully home onto the gas valve. I have see it so many times as its hidden behind the PCB. Is the gas switched on...you are not on a pay as you go meter and it has run out?? or switched into safe mode??
  20. S

    worcester 350 combi hot water fault (shower)

    how hot does the water get when it comes on?? The shower may be stopping the hot as it is too hot. and not switching back on???