  1. S

    Ariston MicroGenus MFFI 27

    Why not get a contract with BG or get a fixed price repair for £170.
  2. S

    Vokera Maxin 28e boiler problem

    Ignition control box on the gas valves are common fault causing lock out on these boilers. However first I would be checking the fan venturi's. and thats not a DIY job.
  3. S

    new boiler advice

    Rads might be ok if they are not filled with debris and have cold spots on them?? Do they heat up all over to the point where you cant really touch them?? Old rads are never as efficient as the new ones with nice converctor fins and panels on the to look nice. Lastly however, if the...
  4. S

    A Well Designed Boiler

    A client quoted me that line about an Isar we had fixed numerous times in there house... good old only fools!
  5. S

    Worcester 28CDi burner lockout

    Magnaclean, great product, follow the destructions, its fairly straight forward!
  6. S

    replacing an IDEAL ICOS condensing gas boiler?

    Viessmann, get an approved installer for a 5 year warranty and 25 on the heat exchanger.
  7. S

    Ariston micro Genus 27MFFI

    the DHW HE can be done in situ. just a couple of allan bolts and its out, some times the gas valve has to come out to allow it past. A power flush would be a good idea as would be a magnaclean filter fitted on the return from the CH. If you have debris in the system then after the abouve...
  8. S

    Powermax 155

    There is nowt wrong with you vessle if the Saftey blow off is dry and the pressure only goes to 1.7bar when heating is on. You are looking for either a leak on the CH pipework or the plate heat exchanger can pinhole and act like a venturi sucking the water out the heating system. The later is...
  9. S

    Worcester Bosch Reset switch (again)

    What works?? Hot water, heating or neither?? Which heat exchanger did they replace?? Pump, Heat exchangers, divertor valve jammed mid position, gas valve not modulatiing for some reason, there could also be a blockage in the pipework from the heat exchanger. This boiler is getting on a...
  10. S

    Potterton Combi Boiler Problems

    Sounds like the CH thermistor could be on its way out. Boiler cuts off....thinks its hot...pump carries on running...thinks its still hot.... thermistor....goosed! :D
  11. S

    Ariston micro Genus 27MFFI

    I agree, DHW plate heat exchanger is blocked.... These can be removed and flushed, and refitted but its your donald duck if this will work. If you do get a new one get a magnaclean filter fitted on the return to the boiler aswell as this will protect your investment. Helps to reduce the...
  12. S

    Ideal Isar He24 installed

    Its the way the combi boiler works.... takes a few moments for the boiler to sense a tap running then fire thus a load of cold water has passed through the boiler. you will alawys get cold hot cold hot hot hot..... on most combi's. As for your preheat...have you got any dripping taps...
  13. S

    Lynx potterton 2 (CH issue resting & Noise)

    British Gas will do a fixed price repair on you boiler for £170 - £200 depending on your location or you could go onto their maintenance scheme with a breakdown included in the price for about £300 over the year. The later is a better solution for an older boiler as it will get an anual...
  14. S

    Baxi Bermuda 51/5 Electronic Controls

    Fixed price repair from BG is you best bet.... £170 - 200 depending on your location
  15. S

    Systemate Hotwater Problem

    I think you could be correct in your diagnosis! A very common fault on the gledhills!
  16. S

    Glow worm 35f spares

    Your local HRPC will sell you one. HOWEVER!!!! This is a positive pressure case on this and not very suitable for a DIY repair.
  17. S

    radiator only heats up when other rads off. Please help!

    How about getting BG in for a fixed price repair. for £170 they can change the pump. Speak nice to the Engineer and they will give you some advice.
  18. S

    Potterton Boiler - Strange Sounds

    look at the pressure gauge under the boiler, this should be between 1 - 1.5 if its a zero then there is not water in the system, hence banging. Fill up and see how you go!
  19. S

    280 worcester bosch combi boiler

    Over heat tripped?? in side the outcase on the top of the control panel?? Fan seized?? Fan is a specialist job though and should not be DIY'd! BG will do a fixed repair for 170 - 200 including parts and labour!
  20. S

    Gledhill Boilermate thermostat replacement

    Your new stat doea not need the neutral. put a connector over the wire then live to 'A' And switched live to 'B' although if heating is then on when it should be off and off when it should be on then swap that to 'C'