Search results

  1. B

    Hot water timed "On" period not always activated.

    Many thanks for your replies. When I said the H/W D/Valve sometimes does not open, I meant that on those occasions the lever on the top of the motor valve remains sprung after the "timed on" period has started. I then open the valve manually by moving the lever against the spring action, and...
  2. B

    Hot water timed "On" period not always activated.

    Boiler: Worcester GS 30cdi installed August 2013. Programmer: Potterton EP2002. Hot tank thermostat: Honeywell L641A1039 set to 55 deg. Programmer settings: Boiler ON, Hot Water, TIMED (Mon-Fri 06.15 to 09.00, and 16.30 to 17.15, Sat/Sun 06.30 to 10.30, and 16.00 to 1900.) PROBLEM: Hot water...
  3. B

    Removal of decor panel from Bosch dishwasher SGV46M03GB

    Many thanks for your replies. It is an integrated dishwasher, in the middle of a run of "framed" kitchen units. On the inside of the dishwasher door, there are three star-head screws down each side, and four acrossthe top. What I really needed to know was which screws to remove. In the end, I...
  4. B

    Removal of decor panel from Bosch dishwasher SGV46M03GB

    The wooden decor door panel on my Bosch dishwasher has swollen, making it very difficult to open the door. Can anyone tell me which screws to remove from the inside of the door, and the full procedure for the removal of the panel please?
  5. B

    Salamander Negative Head Shower Pump - frequent hunting.

    My current pump is quite a few years older than the previous comment to mine on this thread, so I thought it might prove helpful to anyone looking for helpful suggestions now, as I was. I guess sarcasm and the use of capital letters is thought to be helpful by some contributors. I will stick...
  6. B

    Shower Pump Hunting Problem

    That's true Muggles, and I did see that. The reason I replied is that the thread, and my information given by Salamander today, may still be looked at even now. After all, I did that myself, and found it quite helpful. Even if you don't think it's worthwhile, other people might have a different...
  7. B

    Shower Pump Hunting Problem

    To prevent "hunting", Salamander tell me that you need to: 1) Remove the metal dust cap from the valve on the end of the cylindrical metal pressure vessel. 2) Connect a car/bike footpump to the valve. 3) Pump until the pressure is 20psi. 4) Remove the footpump. 5) Replace the dust cap. I hope...
  8. B

    Salamander Negative Head Shower Pump - frequent hunting.

    Salamander tell me that you need to: 1) Remove the metal dust cap from the valve on the end of the cylindrical metal pressure vessel. 2) Connect a car/bike footpump to the valve. 3) Pump until the pressure is 20psi. 4) Remove the footpump. 5) Replace the dust cap.