  1. G

    Vaillant Vantage H/W Stat

    Does the boiler make any noise on heating?
  2. G

    Ideal standard stuff any good?

    I'd agree with Shorky Ideal Standard, Roca or Twyfords B&Q, Bathstore and cheap not good and I've even found expensive Villeroy Boch stuff horrible to fit as nothing lines up properly
  3. G

    Heating Controls - which brand

    It's funny how everyone recommends the controls that they fit when controls covers so many products. Programmer/timer - I find Drayton are rock solid. Nice and easy to work. Honeywell have more feautures but have had some problems with their digital timeswitch. Potterton the sliders always go...
  4. G

    Vaillant problem

    Is the diverter valve moving into the CH mode? If not then it will just circulate through the plate hat exchanger reach temp very quickly cut out then do it all again. If it is a diverter problem on an Ecotec change both diverter and pcb if an Ecomax just the diverter. Ecotec diverters...
  5. G

    glow worm 30sxi fault

    From your description there are a few things to check. As your getting multiple fault codes and a seal failure check that the wiring harness hasn't been damaged by heat. Sometimes the boiler will cut out on minimum rate and constantly keep going through the ignition sequence till it goes...
  6. G

    Glowworm Flexicom 30CX - water coming back via the exhaust

    The outer flue pipe should actually be installed horizontally as the fall back to the boiler is built into the inner flue. I have come across quite a few on these and nearly all are BG installs with that shi**t angled terminal that points upwards. Is it a BG install? So I'd say make sure...
  7. G

    Need help with Baxi Solo fault

    It's a definite possibilty. The flowswitch is there to prove to the boiler that there is circulation. By the sound of other posts you've checked that you have water and the pump is working. If flowswitch on boiler is faulty then it won't tell the boiler that the pump is running and won't...
  8. G

    Vaillant turbomax vuw 242/1 e - keeps needing reset

    In my experience if there is a blockage it's usually on the chrome fixed pipe rather than the copper capillary tube between the PD switch and diverter. Don't start going down the PCB route I'd be 99.9% certain it won't cure the problem.
  9. G

    Megaflow won't switch off - help please?

    Difficult to say without seeing it
  10. G

    Need help with Baxi Solo fault

    Baxi solo HE isn't that basically a rebadged barcelona with updated pcb? If it is doesn't the boiler have a flowswitch on it?
  11. G

    Megaflow won't switch off - help please?

    do it all and picasso will be spot on when saying your having problems with a motorised valve. Probably in your airing cupboard there will be two little boxes connected to your pipework. One one pipework linking up to the cylinder and another that will be on the heating pipework. If they are...
  12. G

    glow worm f9 fault

    F9 was the global fault as this was all the fault codes went up to on older glowworm models. 3 things you could do 1- get glow worm to plug in a unit called a diacomm to diagnose the fault 2- fit a new universal display pcb with all the new fault codes to help diagnose fault 3- Take a punt...
  13. G

    MIs for Saunier Duval Thelia Twin 28E

    That's the one with the unvented cylinder bolted onto the side isn't it? If your stuggling to find saunier duval MI's try looking for glowworm extramax as it's the same boiler
  14. G

    glow worm 30ci problems

    It's the spark generator it makes the spark to ignite the gas. If there's a dodgy connection it might not be sparking. No spark, no ignition..... no ignition, F1 fault
  15. G

    glow worm 30ci problems

    Just a possibility but with you saying that the F1 fault started after changing the valve could you of disturbed the connections to the zig ignitor, that is just to the left hand side of the diverter assembly. If it's original it will be a little black box with a screw holding it onto the casing
  16. G

    Sd30e pressure rising and falling. Still got problems .

    Is there a silver braided hose connecting the EV to the boiler as these are can quite often block up. Bit of a tip for you ......... let the air pressure out of the EV before removing the hose or sh*tty black water will spray out everywhere.
  17. G

    Problems installing Shower

    3 showers not working maybe you should be thinking more of problem with electrics than showers
  18. G

    Vaillant TURBOmax VUW 242/1 E,282/1 E

    If it's the /1e version with the honeywell gas valve then you need to check that you have gas going to it, that you have 240v coming off the pcb to the gas valve. It might be the gas valve but can possibly just be the diode in the gas valve lead that has failed
  19. G

    Vaillant TURBOmax VUW 242/1 E,282/1 E

    The temperature guage on the front is just shows what the temperature of the water is and doesn't affect how the boiler works at all. Can you give more details on what is happening with the light sequence on the left hand side and also if the heating and/or hot water begin to heat up in the...
  20. G

    vaillant ecotec 831 leaking

    Take your pick from flexible hoses, pump or diverter valve. As there is little info then I would guess at the spindle on diverter valve leaking