  1. M

    Self adhesive gerflor vinyl planks

    Chipboard is too unstable. It also contains waxes etc that will impede adhesive strength and can also react with the product. Also make sure you are using the correct type of plywood. i would recommend 'Hanson plywood SP101'.
  2. M

    Do I need to put in a new DPM?

    I have skimmed over the posts and from what im reading you are ALL wrong in some way or the other. Suggestion for the regular posters on here. As most know i run the FloorSkills training centre, we do sub-floor prep courses. If one of you want to arrange a 'DIYNOT' training day then i will...
  3. M

    secondary underfloor heating, how long to warm up tile?

    the consumer expects this as miss sold . However as my above post you should not raise temperatures up and down fast.
  4. M

    secondary underfloor heating, how long to warm up tile?

    Thats correct, providing you dont expect to be able to heat the flooring up by more than a few degrees.
  5. M

    secondary underfloor heating, how long to warm up tile?

    Underfloor heating should not be turned on and off. It should not change its temperature by more than 2-3c over a 24hr period. Floorcoverings fail when it is turned on and off. So the answer to your question, it should take no time to heat as it should always be running at a low...
  6. M

    How to clean up after possibly asbestos floor tile removal?

    care should be taken on what advice is given on a forum ! read here - http://www.hse.gov.uk/pubns/guidance/a23.pdf
  7. M

    Is levelling a subfloor before insulation necessary?

    most water based compounds can only be used over a dry base ( below 75% RH) . A base takes approx 1mm per day to dry. As for teh concrete subfloor teh bouilder has supplied, well he should of been given a specification to work to. In domestic property in is normally SR2. SR is a reg that...
  8. M

    computer help needed please (usb storage)

    Hi, i was referring to the HP tool. Some how i missed your post ? Had a look at your link and to be honest its a little to complicated for me along with the amount of time it will take me. Im hoping for a programe that will pretty much what your link does for me. Problem is i have a fair...
  9. M

    computer help needed please (usb storage)

    yes, they want £1.25 i think it was per usb to unlock them.
  10. M

    computer help needed please (usb storage)

    hi, thanks. I gave this a go but it still comes up the usb is write protected and can not format. Any more ideas?
  11. M

    computer help needed please (usb storage)

    Hi everyone. Not sure if posted in the right place?? Im after some help. I purchased 500 usb pens to give out to potential customers etc. When i purchased them they asked me if i wanted any data added to them. Well ye it will save me doing it so i went with the offer. Anyway, the data...
  12. M

    Vinyl tiles: corners not meeting

    o dear. May i suggest you recommend to the company to send there installers on this - http://floorskills.co.uk/flooring-training-courses/lvt-basic-2-day
  13. M

    Screwing plywood to floorboards - screws not going flush

    6mm plywood for flooring should be installed with ring shanked 22mm nails. Switch to RING SHANKED nails.
  14. M

    veritas r8 false alarm problem

    I have 4 PIR's. 1= Hall 2= Kitchen 3= Lounge 4= Dinning room. As for the other zones i dont think they do anything. The bell box is same age as alarm (10+ years) It is protected from rain as sits under the eaves of the house roof. I cant get a picture due to where it is mounted. I...
  15. M

    veritas r8 false alarm problem

    2 years old at a guess. We had a power cut a few weeks ago and my alarm was fine. The neighbors alarms was ringing away so dont think i have a battery issue.
  16. M

    veritas r8 false alarm problem

    Hi everyone. I have a veritas alarm. I think its a R8 judging by google images i have found. I had my first false alarm in the middle of the night since the alarm was installed maybe 10+ years ago. must say i crapped myself as i went down stairs expecting to be greeted by a burglar...
  17. M

    110v vs 240v on building sites.

    Tech question here then as what you say has got my brain working for the first time in a while ! (interested basically and totally off topic with my original question) So on a average street there is 3 phases and a neutral . My question is - is that neutral cable the same size as the phase...
  18. M

    minimum pipe depth?

    thanks for the replies. I have not done this personally but seems very common with a lot of floor layers hitting pipes when using gripper that is pre-nailed to the correct BS standard for floor-coverings. I run a floor-coverings training centre and we often gets calls regarding the...
  19. M

    110v vs 240v on building sites.

    good point !
  20. M

    110v vs 240v on building sites.

    so then, how come 240v is not ....120 - 0 - 120 ?? Would that not be safer in our homes??? In country's with 120v is it the same setup or the same as our 240v?
Back