  1. J

    Model Please

    :shock: :shock: Really? I'm only an RGI, so if you can't identify them, how the hell can I or other RGI's? James.
  2. J

    180deg bend in hard copper?

    What size of copper tube are you wanting to bend? James.
  3. J

    Modifying Washing M/C Waste Standpipe For Combi Condy Line?

    You'd get the same readings if the standpipe trap was full. The reason why you got those readings is because the condensate trap on the boiler had dried out. But good precaution really as like you said the condensate pipework is part of the flue system. James.
  4. J

    Worcester 29 condenser boiler not working

    Hi, welcome to the forum. Does the boiler look like it is waiting for a demand, i.e. not in a fault? James.
  5. J

    Modifying Washing M/C Waste Standpipe For Combi Condy Line?

    Cut in a 40mm compression tee on the wash mac upstand. Then pipe across in 40mm to condensate pipe. James.
  6. J

    Need to find the part name

    What you are suggesting will more than likely contravene Water Regs. James.
  7. J

    Low pressure

    1st picture, end of flexi hose at the bottom of the pic is a chrome plated valve, turn that yellow bit in the middle. This would have had a small handle at some point but has obviously been misplaced. James.
  8. J

    Low pressure

    By the looks of it, you just need a set of grips/a spanner on the bottom valve. James.
  9. J

    Is this an airlock in my power shower?

    Ok, so that valve is not required. As the problem is with the hot and the valve is installed on the hot pipework, it will not harm the system to remove this valve. Before refilling, I'd be tempted to remove the shower valve as before and then check flow through hot and cold supplies. If the...
  10. J

    Is this an airlock in my power shower?

    A quick scan through the manual shows that a NRV is only required if the pump is above the hot water cylinder. Is the shower it serves the only outlet from the pump? Are all outlets from the pump at least 600mm below the water level in the header tank? Salamander CT50 installation manual...
  11. J

    Is this an airlock in my power shower?

    If it is a check valve, I'd remove it and replace with a non-return valve. Check valves are used for backflow prevention (to maintain water quality). The test point is used to ensure the valve closes if flow is reversed, ie not much help in your situation. What model of pump do you have...
  12. J

    Is this an airlock in my power shower?

    I'm sorry but it looks like a check valve as the screw is used for testing. What should have been fitted, (if required) is a non-return valve. The main difference is that a non-return valve has less resistance than a check valve. James.
  13. J

    Is this an airlock in my power shower?

    If you look at the hot water outlet on the pump, there is a brass valve. This could be sticking, restricting the flow through pipework. As for the banging, hard to say without being there. James.
  14. J

    Is this an airlock in my power shower?

    Edit: Deleted double post. James.
  15. J

    Is this an airlock in my power shower?

    Try the following: Isolate pump. Isolate cold and hot supplies to the pump. Remove shower mixer valve. Slowly turn on the hot water valve and check flow through to valve. Repeat for the cold. Reassemble and reinstate water supplies and electrical supply to the pump. If these are...
  16. J

    Pressure testing

    I'd check your maths dear boy. But agreed, use water not air. Air compresses, water doesn't. Plus a drop (leak) on a water test is easier to detect. James.
  17. J

    Pressure testing

    Ah, sorry my answer is for copper systems. I think it's different for plastic, check manufacturers specifications. James.
  18. J

    Pressure testing

    1.5x the maximum working pressure. James.
  19. J

    Fan Assembly Disintegrated

    If I was to respond in a similar way to the three above, I'd normally get slammed by someone saying that I'm scaremongering and that it's ok to carry out gas work on your own appliance (not used at a rental property) if you are competent to carry out the work. Anyhow, if you are asking on a...
  20. J

    Shataff toilet spray

    Or maybe they should sack their current cleaner. James.