  1. W

    Heating only comes on with hot water - why?

    May be end switch failed on 3 port valve so when calling for both it drives to mid position but when cyl stat satisfied won't make switch. For time being just turn cyl stat to max & blr stat lower
  2. W

    Mclaren 240V Gas Valve - Glowworm Super

    It is 24v & i have one assuming you want the 1/2" one
  3. W

    ferroli modena 102 help please:)

    Just watched video & at no time did the dhw diode come on so it may be dhw flow switch not operating (i assume you had the hot tap running)
  4. W

    2 radiators not working-help please..

    Have you got thermostatic rad valves? if so pin may be stuck so remove head & pull pin out. Sometimes valve may need a tap also to free valve seat
  5. W

    Potterton Netaheat 16-22 Mk11 F

    Very old boiler which doesn't have a pilot potentially very dangerous for anyone to mess with as it has a positive fanned flue so get some-one in or get rid
  6. W

    hot water in header tank

    Is it pumping over? If so may be a blockage (if on a cross vented "h" system) but i am guessing as limited info posted
  7. W

    pilot flame can not remain

    t/c lead o/h stat or gas valve all to be done by corgi reg eng
  8. W

    Condenser only lasts 6 years?

    I fully expect my vaillant ecomax to last at least 15 years
  9. W

    RF Programmable Stat

    If your heart is set on that particular stat then try phoning worcester otherwise just use any other stat
  10. W

    Vokera Linea 28 clock wiring

    What with only 2 wires!! The digistat is a switch with an inbuilt relay operated by batteries so run a 2 core flex from room stat connection on boiler. If you are using a wireless digistat use 4 core live, neutral & as with hard wired
  11. W

    Leaking radiator valves in sealed system

    Does it say bs2767 on plastic top of valve? if not change them all as the rest will start leaking as well
  12. W

    Vokera Linea 28 clock wiring

    Try ringing vokera but it would probably be better to fit a digistat instead
  13. W

    Lots of problems with Vaillant Boiler, not sure what to do

    A common fault on these is the diverter valve. To test make sure htg is turned off & allow pipes to cool down turn on hot tap & feel 22mm pipes leaving boiler, If one of these is hot then you will probably have the earlier valve which will need changing as most of the blr performance will be...
  14. W

    No TRV on the hall radiator.

    Turn stat up or consider moving it
  15. W

    Pump and Rad Problems

    Is it a sealed system? have you pressurised boiler? what boiler is it? etc etc etc
  16. W

    microgenus 23 hot water fault

    Likely cause is incorrect gas valve pressures or thermisters out of range
  17. W

    Heat exchanger gone?

    If you have a plate heat ex then that is the culprit. If you have a dual pass main heat ex then that is faulty
  18. W

    Advice needed replacing a Rad and TRVs in Microbore

    Just use reducing olives & throw away the 15mm olives that come with valve
  19. W

    Boiler timer not working

    If you have got a thermostat change it to a programmable one if not put in a remote timer next to boiler. The 4 wires are live & neutral then the 2 switching wires
  20. W

    baxi bermuda inset 3 boiler

    If i remember rightly the gas valve is causing ign boxes to fail so both should have being changed originally