  1. T

    Shower install on combi boiler

    Combi boiler should give much better flow rates with a suitable thermostatic mixer shower ,than any instantaneous electric shower could. Pumps and combi boilers are not used together .
  2. T

    Suspected blocked feed t on heat only system

    I wouldn't use one of that type of isolation valve ,better to have a full bore ,good quality,lever operated valve.
  3. T

    Suspected blocked feed t on heat only system

    If there is an isolation valve on the feed from the loft tank, and it's above the Tee that you suspect may be blocked, close it and drain some water out the system from a low point. If the isolation valve is a gate valve ( usually with a large ,red coloured ,wheel head) be aware that they are...
  4. T

    Worcester Bosch Boiler problem

    You should start your own thread and give us more info ,rather than taking this one off topic.
  5. T

    Worcester Bosch Boiler problem

    How old is your boiler ?
  6. T

    Worcester Bosch Boiler problem

    Couple of hundred quid most likely, probably more if you are in/ around London.
  7. T

    Worcester Bosch Boiler problem

    The plate heat exchanger is where the cold mains water is heated as it passes through on its way to hot water taps,it has no part in the central heating function.
  8. T

    Worcester Bosch Boiler problem

    I would suspect a blocked plate heat exchanger.
  9. T

    Worcester Bosch Boiler problem

    Could be a number of things including a blocked heat exchanger ,does it run for central heating , not that I expect you would have it on in this weather ?
  10. T

    Worcester Bosch Boiler problem

    You need an engineer to visit. What's the temperature of the water coming out the hot tap?
  11. T

    How to attach 35mm brass bottle trap to solvent weld 40mm waste pipe

    The heading of the thread tells us it's 40mm solvent weld pipe. You need to reduce that to 32mm, as already advised.
  12. T

    Water in electric shower just stopped

    That is not a nut. The 4 segments need to be pushed inward,they are a bit like springs,and the solenoid pulls straight off.
  13. T

    How to attach 35mm brass bottle trap to solvent weld 40mm waste pipe

    You can't connect this directly to a 40mm waste pipe.
  14. T

    Relocating radiator and extending pipework

    Probably worth asking a plumber to visit.
  15. T

    Relocating radiator and extending pipework

    Does a magnet attract to it ? Can you see where any copper pipe joins to it and show us a picture of the joint ?
  16. T

    Water in electric shower just stopped

    Yes ,you can buy a new solenoid. But first you need to establish the voltage at the showers main terminal block between live and neutral is 230/240 volts. The solenoids resistance can be checked with a multimeter to determine if that's at fault .
  17. T

    Water in electric shower just stopped

    Either the shower unit is not getting a 230/240 volts supply ,or there is a fault within the shower ( possibly the solenoid). You would need an electrical testing instrument to determine which it is.
  18. T

    Oil boiler CH pipe work questions?

    Boilers fitted on the ground floor very often have flow and return pipework run upwards ,and back down to ground floor rads , particularly when ground floors are concrete .
  19. T

    Oil boiler CH pipe work questions?

    I wouldn't think so. Generally speaking ,pipe runs should be as short as possible ,but if it's not practical to take the direct route ,so be it.