Search results

  1. D

    10mm shower cable

    My submains, 4mm ish singles! (with tape). DSDSCF1036 by deadshort posted 26 May 2016 at 9:04 PM
  2. D

    Garage light but no sockets!

    Post a pic of the garage rcd please. You may have a FCU with a fuse fitted and the lights may be wired to the feed side! DS
  3. D

    Supply for utility room from upstairs ringmain + a further question

    You can still buy rbo's for the board. You have not actually added any circuits ? You have moved a socket and replaced a damaged one. If you add a circuit or a socket the addition should have RCD protection. DS
  4. D

    Replace old double hallway switch- what do I need to buy ?

    It is no different from replacing a socket or ceiling rose. DS
  5. D

    Advice on poor standard on electrical work i've had carried out.

    The standard of electrical work on this particular job does not appear to be unsafe judging by the CU install the installer has some skill and standards. DS
  6. D

    Advice on poor standard on electrical work i've had carried out.

    Well, if he delivers as promised you can't complain ! DS
  7. D

    New Cooker Circuit Advice

    Yes to both your questions :) DS
  8. D

    EICR needed - consumer board replacement cost?

    Well, you appear to have no earth connection for a start. DS
  9. D

    Advice on poor standard on electrical work i've had carried out.

    If they rewired and fitted a new CU, (fuse box) post a pic please ! DS
  10. D

    Advice on poor standard on electrical work i've had carried out.

    What you have here is a fine example of "the house basher" sady, not rare ! I would give them the opportunity to put it right in the first instance, and see what response you get. DS
  11. D

    Replace old double hallway switch- what do I need to buy ?

    And buy some earth sleeving of those bare copper earth wires, just to tidy it all up when you've fitted your new switch :) DS
  12. D

    Rewiring plan

    How camp is that !:LOL: DS
  13. D

    Rewiring plan

    Must be a fault with the system? DS ++++++++++++++++++++ edit 19/7/17 Now fixed mod ++++++++++++++++++++
  14. D

    Rewiring plan

    Don't use MK ! Hager, or BG, If on a budget. You don't need 2.5mm for your boiler or alarm The separate circuit for the freezer is a good idea. Install 2 single sockets instead of a double if you have a TD and WM in the same location. If the external socket is fed from ring, add a DP switch...
  15. D

    DIY chandelier junction box advice

    Electrically its fairly straightforward, there will be a join box in the centre where all the tails to the individual lights connect to a single supply cable. You can use a single 1g 25mm box and a blank plate as your join box. DS
  16. D

    The Mains Supply Cable - has been uncovered

    Dont touch it! To be on the safe side call the DNO and ask them to have it checked. DS
  17. D

    My Domestic Wiring

    If this is not a ring you need to derate the 32A to a 20A MCB. Regards, DS
  18. D

    My Domestic Wiring

    Disgusted. DS
  19. D

    Supply for utility room from upstairs ringmain + a further question

    Don't be sorry about asking, that's the point of this site. :) It is not best practice to have all the sockets on one RCD. To avoid complete loss of power, and makes it easier to find a fault, it is advised that the circuits are protected by two separate RCD's. DS