Search results

  1. D

    Pyronix Enforcer V11 trouble setting zone D

    Push D enter your master manager, not your engineer code. If you only have 1 code it might be this. Select no through to edit users, choose the user needing amended, again there may only be one, select no and scroll through to where the zones for the user are shown / illuminated and amend...
  2. D

    Pyronix Enforcer V11 trouble setting zone D

    When your in the edit user screen you’ll be asked to assign what zones A through D each user can set and unset. If your saying the user cant currently select D then you haven’t chosen it to be possible in the user setup. You need to set each user with what zones you want them to be able to use
  3. D

    Pyronix Enforcer V11 trouble setting zone D

    You need to edit the user and add the respective zone to the user code in question
  4. D

    MC1MINI-WE - Pyronix Door Sensor 3 LEDs

    If it was installed by a firm they will more than likely have changed the code from its default. If they have it will be easier to contact them for the information.
  5. D

    MC1MINI-WE - Pyronix Door Sensor 3 LEDs

    You will need to delete the old input and relearn the new one. You’ll need the panel engineering code to be able to do this.
  6. D

    Unusal request probably.

    There’s a couple of options. One relatively cheap, less than £20 at the link below, the other being trading in the wife for a new model that needs less from you. This would be the more expensive option but likely still worth giving some thought too. https://amzn.eu/d/biF6wsr
  7. D

    MC1MINI-WE - Pyronix Door Sensor 3 LEDs

    What do you mean reset the main enforcer?
  8. D

    MC1MINI-WE - Pyronix Door Sensor 3 LEDs

    Remove the battery and leave it out for a bit then put it in the right way. See if you can relearn the input. If all that fails then you’ve fried the board by reversing the polarities.
  9. D

    Pyronix Enforcer Area help

    As you go through changing each input you can choose what areas they are on and off for. If your using D for your cunning plan simply add the doors and upstairs sensor to be active in D
  10. D

    Boiler firing on cold

    So providing I put up with the annoyance no problem doing nothing?
  11. D

    Boiler firing on cold

    Thanks. There are lots of dead legs hence looking to check whether leaving things as is would be a problem?
  12. D

    Boiler firing on cold

    Had an extension fitted, some rads moved and a new boiler fitted and since then my combi system is firing up briefly when there is a cold water draw from either a tap or toilet etc. This happens after the cold draw and I’ve read plenty to indicate it’s likely caused by air being trapped or a...
  13. D

    Pyronix battery query

    Enter your code and it should cycle to a more detailed message showing what device Alternatively you can push D, enter your code, go into review logs, find the log in question and push C for more information.
  14. D

    Pyronix enforcer unable to set message

    The lid will be the lid looking like thing that covers the board The spring is the thing inside when you open the lip that looks like a spring The back tamper is the only non obvious thing to someone not used to the kit but can be found on the back and it’s a little plastic nipple sitting off...
  15. D

    How to program Pyronix Enforcer wireless magnetic contact for a door

    If you program the input to have chime enabled you’ll get a chime on the panel each time. Make sure c is displayed on the panel Home Screen as well as programming the input. If it isn’t you can simply press c to enable this from the Home Screen
  16. D

    How to wire a replacement smoke alarm (Ed.)

    Is that a no to my last question then?
  17. D

    How to wire a replacement smoke alarm (Ed.)

    Nope, have you to validate its as advertised, an absolute no no?
  18. D

    How to wire a replacement smoke alarm (Ed.)

    Yup good example Deta say don’t mix and match even within brand. Mix and match fine when I’ve done it and all trigger and remain interoperable with other heat and smokes.