  1. A

    Cabling for motorised valves

    Damm. This one runs of immersions. So Doesn't show boiler pipes. But you get some idea
  2. A

    Cabling for motorised valves

    Unvented cylinders do not need to be at the top of a house, as they run off mains pressure, with a small reduction. Basically you have the mains water come into the "airing cupboard". Then you have a pressure reducing value with 3 outputs. 1. Water out supply to water cylinder 2. Water out to...
  3. A

    Cabling for motorised valves

    I don't know who mentioned explosions. But you can't just leave unvented cylinders unmaintained for years, else they will fail early and have to be replaced at cost ££££ Good news is that is easy to do yourself. Once a year you just move 3 valves/taps for ~10 mins, draining off the expansion...
  4. A

    Dual tariff unit

    There is a rule of Thumb. For example, if you use 70% of energy at night rate in winter, then you are better of on E7
  5. A

    Converting old heating control to socket

    I reckon normal metric screws. Yellow conductor, and g/y cpc sleeving present
  6. A

    Dual tariff unit

    You have grey tails currently.
  7. A

    C U main cable SWA

    Badly usually ;)
  8. A

    Stairwell lighting went off, needing advice

    something has caused the fuse to blow. Could be the sensor or cable
  9. A

    Converting old heating control to socket

    So you could fit a 10A fuse in the fcu and run almost anything on a single socket. Don’t think there are many things that use the full 13A these days.
  10. A

    Converting old heating control to socket

    Don’t test to the blue ! Test to black or earth
  11. A

    Converting old heating control to socket

    Some where there should be an fcu with 3a fuse to turn it off. The live is the red wire on the left. The hole spacing is designed to fit a single socket. Depends what you want to plug in really or just make it tidy?
  12. A

    Cabling for motorised valves

    "I've extended the CH pipes to where a cylinder would go" Obviously think about summer time (for example). You need boiler hot water to the cylinder when the heating is off. The return can be combined with the CH return. These days you also need a bypass valve, for when all the motorized...
  13. A

    Dual tariff unit

    No, it won't magically switch. You can get external contactors, so I would go with one of them, switched by the signal provided...
  14. A

    Dual tariff unit

    A pic of your cu and meter setup will help.
  15. A

    wiring up a lighting photocell without a neutral wire?

    I think they actually use the voltage drop across the triac to power the electronics
  16. A

    wiring up a lighting photocell without a neutral wire?

    They don’t need neutral, but you must use an incandescent lamp. Sadly no battery to charge. The second the bulb fails or the power goes off, they loose their memory
  17. A

    Gas main earth bonding has been removed

    You would like to hope an EV installer would fix easy and dangerous things when pointed out to them. All of 10 mins to sort. Don’t they have some basic checks / forms to fill in. Says a lot about the ev cowboys too
  18. A

    Kitchen lighting ideas?

    Didn’t need to drill hole for click connector as they fit between light and ceiling in my case
  19. A

    Kitchen lighting ideas?

    Yeah I am liking the panel lights from Www.lights.co.uk 16% off at present. Common to have 13% off offers Got 4 of them now. Over 3 rooms. First 2 purchased in 2021 When replacing 6ft tubes I did have to make the plaster look tidy on the ends. Light output is great. Can’t believe the spread...
  20. A

    Aico alarm wiring instructions

    It would make sense if you wanted 2 neutrals in the cable.