    advice on lighting circuit please

    The easy way is to find the last light with only 1 cable and run from that
  2. A

    Shared earth conductor

    When I previously asked, it wasn't a problem. Just need to ensure the cpc is thick enough to cope with the biggest cable/circuit
  3. A

    Splitting existing loft light which uses 3 core and earth

    You maybe able to use the rose as a junction rather than buy expensive wago
  4. A

    Age of installation

    If it is, I think we are only talking about 10 years.
  5. A

    Age of installation

    I'm not sure that 6mm is tinned. Anyway, it's metric cable, and green/yellow sleeve. So sometime after 1974 The fact is has 30ma, points to 80's
  6. A

    2 way switch and change of cable ?

    Exactly as sunray says. Also in modern insulated houses I have a ceiling and fan light combined. With this I prefer not to have this in a 2 way setup. So I know off really means off. (Rather than being off via the remote control) Defo run 3c&e to the switches. I wouldn’t put an intermediate...
  7. A

    2 way switch and change of cable ?

    Well I decided only one light needed to be 2 Way. (Ceiling or bedsides). So I just made the bedsides 2 way. Anyway. The principle is the same. To make a second switch you run a 3c and E to the other switch. Sockets goto the junction box.
  8. A

    2 way switch and change of cable ?

    Seams too much extra work to me that you may need an extra N at the second switch ! For me I would be putting in a single socket either side of the bed, and extra switch wires by bed and door. So you can have some nice bedside lights switched from multiple locations. And you will be very...
  9. A

    2 way switch and change of cable ?

    probably "joined" under the junction box It keeps all those bare wires away from harm
  10. A

    2 way switch and change of cable ?

    regardless whether is a "new" or "old" layout, best thing to do is run 3C+E between the switches. If you are going to replace the switch drop, leave it long enough to reach a ceiling rose.
  11. A

    2 way switch and change of cable ?

    What are you trying to achieve ? 2 switches to control the light Or a neutral at the switch because of some smart system ?
  12. A

    Which type switch do I need?

    It's an intermediate, (as it says on the rear). These have 4 wire connections. You need to reconnect that 4th wire, that will be why it isn't fully working. So to replace you switches I think you need 2 gang 2 way and a 1 gang INTERMEDIATE
  13. A

    Replace red and black 10mm cable to loft conversion?

    you don't even need the labels these days
  14. A

    Replace red and black 10mm cable to loft conversion?

    A radial will be fine for a loft. 2.5mm cable, 20A circuit protection. But if what you currently have works for you, leave it alone.
  15. A

    Loft lights: 2 circuits

    OCD
  16. A

    Loft lights: 2 circuits

    surprised you didn't blank out the .5
  17. A

    Loft lights: 2 circuits

    I mean its not wrong. That is how you would do it with ceiling roses, but you have LED battens. (so do the junction in them) Do you really need 2 switches for them? LEDs don't consume much. Be simpler with one switch and just take one lamp feed from the other. The other way to make it really...
  18. A

    Trying to upgrade house fuse to 100A

    what the lidl version or the real version ?
  19. A

    Trying to upgrade house fuse to 100A

    and supply Tea and Jaffa Cakes ?
  20. A

    5w 700lumens Vs 7w 720lumens

    Check the life / hours for both.