  1. A

    glow worm compact 80e no hot water

    http://www.glow-worm.co.uk/products/pdf/discontinued/boilers/Compact80E_UIS.pdf If link is o.k. have alook at page37 for diagram. If not go to Gloworm website and look under discontinued products literature. You have to take the lower cover off via few screws It is just to the lower...
  2. A

    Hole in cast iron soil pipe

    Put some metal filler on and paint.
  3. A

    Condensation in Flexible Ducting

    Just a thougth..Make sure ducting is angling away to the external outlet and that no rain is finding its way into the duct from outside?
  4. A

    glow worm compact 80e no hot water

    check if D/h/w microswitch operating pin via housing is working(moving). Can take microswitch off and temporarily put a broken cocktail stick in ( taped over) to see if d/h/w/ works. If it does either pin not operating ( diaphram knackered or seized pin) or microswitch knackered. Try out...
  5. A

    Glow Worm Compact 100e - not firing up?

    Debt, There is a Pressure differential switch that looks very similar to the D/H/W switch set up that you have shown in your picture. It is on the left side of the boiler looking forward and is a pump prover switch ( same housing set up ) This needs to be operating to give C/h or D/w/h. ( via...
  6. A

    Neff Extractor duct reducer

    Screwfix
  7. A

    Ideal Icos boiler - pump overrun

    Pitty that!..Before you go changing anything.Start from scratch, make sure you have bled everything and are running your pump on the lowest speed your system will take.
  8. A

    Cooker hood ducting

    If a new install make sure joists run the correct way with you?
  9. A

    Blomberg dishwasher leaving glasses dirty after wash

    Don`t know about your make but have had similar problem a few times with my appliance and done same things as yourself prior to solving problem. Check the water spray outlets top and bottom ( may or may not detach), you will more than likely find bits of stuff clogging some of the outlet...
  10. A

    gas4you/feedback

    http://diynot.com/forums/viewtopic.php?t=158396
  11. A

    Gloworm Compact 100e - No Hot Water, CH ok.

    diverter diaphram? or did you mean DHW flow switch housing diaphram? Is housing plunger moving out?
  12. A

    Ideal Icos boiler - pump overrun

    http://www.diynot.com/forums/viewtopic.php?t=158396
  13. A

    Ideal Icos boiler - pump overrun

    Iparm, have a look at my posts recently. Have the same boiler and recently had very similar problems. Cured yesterday/today by lowering the boiler stat setting. If it is turned right up I bet you have got the same problem! There are 6 settings including min & max. What one is yours currently...
  14. A

    Grundfos Alpha + pump/Icos He 24 boiler

    Gas, thanks for your previous input. I thought that it would be nice to give a report back for info. Reference my problems within these posts and my last one whereby I lowered the boiler stat down to 1 O`clock position, which I have further upped to midway between 1 & 2 O`clock position today...
  15. A

    Grundfos Alpha + pump/Icos He 24 boiler

    Cheers Gas, Thought there may be a few thoughts in general. Thanks for your input. As per prev have set stat to about 1 O`clock and at present it seems to be sounding good, but will know for sure tonight. Over past week variations of Pump settings sounds fine, right across variable range and...
  16. A

    Grundfos Alpha + pump/Icos He 24 boiler

    Very surprised with all the experience on here that no thoughts!
  17. A

    Grundfos Alpha + pump/Icos He 24 boiler

    Back on this one. Gas...Spoke to Grundfos who tell me it is only 1 yr g/tee on Alpha+ pump. Appreciate input to this.. On the Ideal He24, when you guys install, at what position do you generally set the boiler thermostat at ( including min & max equals 6 settings? Have you come across a...
  18. A

    Grundfos Alpha + pump/Icos He 24 boiler

    Cheers Gas. Installation under 2 yr warranty. Need for pump to be the accepted problem though!
  19. A

    Grundfos Alpha + pump/Icos He 24 boiler

    Hi, Have been getting intermittent kettling noise with loud banging via boiler /pipework. Boiler / pump installed about 18 months ago. Ha sbeen fine until approx 4 weeks ago. Pump is operating and was set betwen 2&3. Enginner upped speed to highest 3+. Calmed down but carried on doing it...
  20. A

    Trying to fix my dads Ideal HE30 boiler..

    wireless thermostat? If so check batteries!