  1. M

    topping up my boiler!

    On my 37CDi combi, you turn the white plastic key to the unlock position and you also have to unscrew a white plastic nut just to the left of this key. You can download the manual from Worcester Bosch's website - it'll tell you in there.
  2. M

    Total failure of loft water tank - flooded house for 8 hours

    My neighbours suffered a similar incident while they were away on holiday. In their case the ball actually came off the arm, allowing water to enter the tank at mains pressure. The tank overflow couldn't cope with this much water and so the whole house flooded. They lived in a hotel for the...
  3. M

    Loud piping and horn noise when we flush toilet

    I had what sounds like a similar problem with an older toilet in my house recently - it would emit a load groaning/roaring noise when refilling, along with vibration in the pipes. I finally tracked the problem down to the two-piece design of the arm that joins the floating ball to the cistern...
  4. M

    worcester bosch dt10rf

    I've got a Mk1 DT10RF fitted to my WB combi, so if you have a Mk1... Divide your day into 3 zones - typically morning (Zone 1), daytime (Zone 2) and evening (Zone 3). Pick a time at which each 'zone' will start. The 4th zone is esentially night-time and is denoted with a moon symbol...
  5. M

    non finned radiators modern equivilent

    The PTS catalogue is a good resource in situations like this, as it contains many pages of radiators from many different manufacturers along with all the stats, allowing you to compare heat outputs and sizes. There were even one of two examples of non-finned radiators in there, allowing me to...
  6. M

    Cold bathroom

    Based on the calculations I arrived at when redesigning my central heating system last year, I came to the conclusion that a medium-sized towel rail on it's own would not be sufficient to heat an average-sized bathroom. I have a fairly small en-suite shower-room with two external walls and...
  7. M

    Worcester Bosch Combi Boiler

    Glad to hear you've sussed it. Try and aim for around 1 bar if you can, although the exact figure isn't too crucial, provided it's above the minimum operating pressure (my WB combi's is 0.75bar - check your manual). When you've got it to a suitable level, check that it doesn't get too close...
  8. M

    Worcester Bosch Combi Boiler

    Not sure, but if it's around 4 bar when cold, then that'll be outside the normal operating temperature of the boiler I would suspect. Personally, I would relieve the excess pressure before using the boiler again. Do you have the built-in plastic filling loop (with key) as found on the...
  9. M

    Worcester Bosch Combi Boiler

    Bleeding air from the radiators should usually cause the system pressure to drop, not increase. Are you sure you've turned off the filling loop properly ? Make sure you do all the pressure testing when the system is cool/cold and aim for around 1 bar when cold. This allows for the extra...
  10. M

    worcester digistat

    If the stat is indeed faulty, then you're probably going to need an electrician or heating engineer. And that's presuming they can be fixed or that it is economical to fix them. Is it likely to be under warranty still ? If it is a DT20RF, then the stat and reciever can be bought online for...
  11. M

    worcester digistat

    P.S. From memory, I'm fairly sure that you should expect to see a display on the stat, even if there is no active link between the stat and receiver (provided the batteries are installed correctly - ie. in the right order) Edit - from Gremlin's post, it looks like the DT20RF behaves in a...
  12. M

    worcester digistat

    My DT10RF says 'Digistat Optimiser' on it so if your's doesn't then it might be the DT20RF. The instructions are here : www.worcester-bosch.co.uk/cache/file/12/dt20rf-digistat--mk-1.pdf Make sure you follow them closely. NB. Edited to include the right instructions !
  13. M

    worcester digistat

    Does it look like any of these ? www.worcester-bosch.co.uk/homeowner/products/gas-fired-boilers-and-systems/greenstar-37cdi/optional-plug-in-controls
  14. M

    worcester digistat

    Seems odd that simply taking it off the wall should cause it to pack in. Which model is it ? I've got the DT10RF Optimising Digistat for my WB combi and I seem to remember seeing that it was possible to buy the sender unit separately, although it's unlikely to be cheap. Make sure you...
  15. M

    Bonding Central Heating copper pipes.

    Well that's what I get for using a local electrical supplies place, rather than my usual B&Q, Screwfix etc !
  16. M

    Bonding Central Heating copper pipes.

    Any ideas why the boiler manufacturers recommend it then ? Is a case of belt and braces and then some ?! At £1 a clamp, that was a fiver I could have done without wasting ! I thought it was to keep the plumbers and/or electricians happy, when they work on the boiler during future repairs ?
  17. M

    Lowish pressure on Electric shower

    What kW rating is your Mira Sport shower ?
  18. M

    Bonding Central Heating copper pipes.

    If the water and gas pipes are bonded to the MET as shown and the pipes beneath the boiler are bonded adequately, would that not amount to the same thing ?
  19. M

    Bonding Central Heating copper pipes.

    rezarf - Worcester Bosch have a useful PDF that shows their recommendations for bonding : http://www.worcester-bosch.co.uk/cache/file/24/equipotential-bonding.pdf
  20. M

    What does this pipe do??

    I can't see any obvious problem with taking it through to the outside at ceiling height, however it might still have to be run down the outside wall to ground level to prevent the potential of dripping hot water on anyone passing below. If you can get hold of the manufacturer's installation...