Search results

  1. hardmetalking

    new member quick zinc roof question

    That would be me :mrgreen: I've inboxed you.
  2. hardmetalking

    Best roofing options for low pitch ground floor extension?

    We are approved installers for Colorcoat urban. The main difference is penetrations through the roof. On a zinc roof all penetrations have a soldered joint whereas you cannot solder or weld Colorcoat urban so the approved weathering of a penetration is sealant. As I've said before on a...
  3. hardmetalking

    Roof pitch for lean to

    Perfect for zinc :mrgreen:
  4. hardmetalking

    Low pitch / Stone tiles advice please.

    Lead or copper wouldn't look out of place IMO.
  5. hardmetalking

    Roof design help/low pitch problem

    Or go for a zinc roof which can go down to a 3 degree pitch. :D
  6. VM Anthra zinc

    VM Anthra zinc

    Modern extension with velux roof lights
  7. VM Quartz zinc

    VM Quartz zinc

    Low pitch with integral gutters
  8. VM Quartz zinc

    VM Quartz zinc

    Low pitch extension
  9. VM Quartz zinc

    VM Quartz zinc

    Low pitch roof section. Almost dormer top like....
  10. VM Anthra zinc

    VM Anthra zinc

    Conservatory roof
  11. VM Anthra zinc

    VM Anthra zinc

    Conservatory roof
  12. VM Quartz zinc

    VM Quartz zinc

    15 degree warm roof extension with stepped verge
  13. hardmetalking

    Venting a breather membrane and condensation

    Yes the same applies Jimbo.
  14. hardmetalking

    Recommendations for making this at a sensible price?

    There are some big bays in that gutter.......... Hope it's code 8?
  15. hardmetalking

    Venting a breather membrane and condensation

    To create an adequate vented roof you need continuous vents at the eaves and ridge to create a positive flow of air. The eaves vent needs to be 1/1000th of the overall roof area. The ridge vent then needs to be 15% larger than the eaves to force the air flow up to the ridge. By installing a few...
  16. hardmetalking

    Venting a breather membrane and condensation

    The most important part of the build up is the vcl membrane! Most builders don't know a vcl membrane from a breather membrane.......very very different things. Oils you be more specific about the vcl membrane?
  17. hardmetalking

    Zinc roof noise

    I strongly disagree but I'm biased. I will record the rain falling on a new zinc roof tomorrow and send you a copy so you can decide for yourself. These roofs have been around for hundreds of years so surely if it was as much a problem as the previous poster suggests there would be...
  18. hardmetalking

    How do I solve this roofing pitch problem ?

    Just use zinc which can go down to 3 degrees pitch and is only 5kg per square metre. :mrgreen:
  19. hardmetalking

    Leaking roof bottom of velux window

    Agree with Freddy!
  20. hardmetalking

    Looks for inspirational roofing for the odd shaped extension

    Firings to create a 3 degree pitch with 18mm ply on top and zinc final layer?
Back
Top