    Recognised plumbing certificates

    'm not disputing that lead work done well is highly skilled work for those that want to do it and yes I have lead flashing on my chimney too..I've just finished building an extension and as I had to get a plasterer in...From my own personal point of view it would have been great to have spent a...
  2. J

    Recognised plumbing certificates

    There is the 6129 Plumbing certificate which is the starting point City & Guilds qualification for Plumbing..If you do this then the next step is the nvq 2 "work based " qualification ...which if you have this defines you as a "Competant person" to carry out most plumbing jobs...my understanding...
  3. J

    Replacing Randall /Danfoss 3060 Programmer

    I've offered to help a friend of mine on this and it will be that does the fitting and therefore will be my problem if it all goes wrong :D Ok the current programmer is a 30 year old 30/60 programmer that is basically worn out...Its a huge ugly thing that apparently was/is popular in local...
  4. J

    Is corgi registered required?

    Chaps..sorry I should have put the title of my answer in the text to make it clearer...I'm studying my NVQ 2 Plumbing and was simply quoting what was demonstrated to us last week as what had to be done by a CORGI registered person in order to legally satisfy the rgas egulations that are in force...
  5. J

    Is corgi registered required?

    ..And you are definately not allowed to do this unless you are CORGI Registered...If the CORGI person does the job properly as per regulations.. The Gas has to be switched off The Gas has to be isolated at the meter by capping it and the supply to the house physically disconnected The...
  6. J

    Dead Boiler

    err it would be nice to know what the problem was mate..we do read these forums to learn too!
  7. J

    Toilet Syphon would not fit..Info required please

    Hi went to help a friend yesterday after I dignosed the diaphragm on her toilet cistern was shot (no flush)..anyway removed the siphon no probs and sure enough that was the problem...I had bought a new siphon to fit which was the correct height (11 inches or there abouts)..Much to my horror when...
  8. J

    Downlights for a Bathroom

    Thanks folks...No i won't even consider taking the risk with them...Off to Screwfix catalogue for some bathroom ones then!
  9. J

    Downlights for a Bathroom

    I have 6 low voltage Halolite Aluminium range 12V MR16 50W Halogen Downlights complete with transformers left over from my kitchen project (slighly over ordered!)....Can I use these in my bathroom does anyone know...I've looked at the zone thing and I guess they should not be placed above...
  10. J

    worcester hiflow 3.5 ch not working

    I have exactly the same problem ..apart from the fact the diverter valve mechanism is clicking..it looks like a brass toothed sprocket has worn on the mechanism...How do you replace the valve on this boiler...I'm worried about flooding the place..Are there any drain valves on this boiler or what...
  11. J

    Velux Window Advice

    All I can suggest is you do as I suggested and look which ridge on the side flashing he has leant the edge of the tile on...I bet he has put them on the tall ridge THIS IS WRONG AND WILL CAUSE THE TILE TO KICK UP..The tile is supposed to butt up to it and rest on the shallower of the ridges...
  12. J

    Velux Window Advice

    Hi Racey...dunno if you used a "reputable" company ..but if you can get them back if you go on the velux site (canada I think) you will be able to prove that they fitted them to the flashing kit incorrectly ..with regards which flashing kit to use I contacted Velux and also the manufacturer of...
  13. J

    Velux Window Advice

    So i'm not the only one to have had complete morons and idiots around who claim to know how to fit velux windows... I had exactly the same problem over the summer...I think you will find...assuming they have fitted the correct flashing kit for your tiles (you can check with velux technical...
  14. J

    Should I sign up for British Gas Cover????

    And at least you will end up buying a new boiler off them after a short time after they tell you your thermocoupler has gone wrong and you can't get the spares anymore :) :)
  15. J

    what do you guys think of screwfix

    Placed a big order with them 6 months ago for loads of stuff for my kitchen extension...A couple of weeks ago got around to fitting the radiators...unpacked one and found it damaged Rang up screwfix in trepedation at 3.30 pm expecting "all damaged good to be reported within 7 days blah blah...
  16. J

    Fire protection..load bearing RSJ

    Actually no..The structural engineer specified a whopper of a beam as basically its holding up the back of the house..the joists run the wrong way to enable the beam to sit high up which results in it being pretty low.. I'm going to look at some of the alternatives suggested..thanks
  17. J

    Fire protection..load bearing RSJ

    Hi, I have a load bearing RSJ in my kitchen extension that i'm building..It overhangs the ceiling downwards and really you would not want it to sit much lower than it is... My question is regarding fire projection...I realise double skinning with plasterboard is the obvious one although i'm...
  18. J

    Have I been overquoted for this tiling?

    ...Well its a builders world at the moment!..To be honest it kind of sounds reasonable if he does a good job...
  19. J

    Velux Skylight tunnel

    I have to construct quite a deep tunnel to fill the gap between the roof and ceiling for the velux I have fitted in my extension...Any tips on how to do it and also what short of angles I should make it ??..Anyone done it???
  20. J

    New upvc French doors & Windows...Fitting advice

    whoops..just looking at the "how to" section now..any other guides folk know of?