Search results

  1. T

    Keeping legs crossed...

    Is the stack also cast Iron. To change the Loo should take no more than a few hours. I always screw toilets down so they can be used staight away. But you will have to ask your plumber his intentions as a lot still bed them in cement on the ground floor if its a screeded floor of course.
  2. T

    New Pump Problem?

    Have you touched the thermostat on the boiler? Is the pump Working?
  3. T

    No gas to house.

    Contact Transco Price depends on how far away there gas main is. They will do a survey and come back to you with a price.
  4. T

    installing a loo

    There is a space saving pan that comes off the wall at an angle dont know if it would help or not?
  5. T

    Micro bore

    Thanks for your help Customer wants all pipe to be hidden, pipe runs per floor are no more than 10 mts per rad per floor. Idea was to have a bank of manifolds on each floor connected to the three port via 22mm pipe work. The only single rad over 10,000 btu is on the ground floor I can run...
  6. T

    Boilers

    Thanks Oilman for both posts Brian
  7. T

    Boilers

    Hi me again Can anyone tell me The best way to test the limit stat on oil boilers without endagering life and limb by taking the boiler to its limit temperature. Thanks Brian
  8. T

    Micro bore

    Thanks for all your lovely info :lol: Customer wants sealed system, customer wants plastic micro bore Anything technical to add. Breezer yes I have lol Brian
  9. T

    Micro bore

    Hi Apart from the usual possible problems with micro bore sludge build up etc, Can anyone advise me of any other problems I may come across when fitting a sealed system with 24 rads all in micro bore hep2o. Thanks Brian
  10. T

    is my hot water cylinder big enough?

    Hi I doubt very much that your cylinder will be big enough to cope with 3 showers. But it all depends on the water output of the pump and how long you spend in the shower. An unvented system is good advice but expensive, or can you fit a larger conventional tank?
  11. T

    new build

    Hi I have been asked to fit heating system in a large house approx 20 25 rads. the customer does not want pipes coming up from the floor, he would like them coming up behind the plasterboard wall then out horizontally to the rad valves. Would it be ok to run the main pipe work in 22mm then...
  12. T

    Cost for changing rad valves?

    I would charge from £50 to £70 depending what the system looked like new old or one big problem waiting for me to touch it.
  13. T

    Replacing old rads with modern

    The standard domestic rad valve is 15mm so I dont see you having a problem changing radiators.
  14. T

    Replacing old rads with modern

    Do you need to change the pipe size
  15. T

    New Toilet!

    :lol: looks like you are right breezer
  16. T

    New Toilet!

    The level in the pan is set by the shape of the pan and the height of the ceramic pipe that the waste pipe fits onto. Your plumber can do nothing to control this height and you will be wasting his and your time by calling him out.
  17. T

    Brown water

    how low is the header tank connection you may be sucking up crud from the bottom of it There you have a reply :)
  18. T

    Speedifit connectors

    Never had a problem with them yet (touch wood) make sure you use the inserts if using speedfit pipe.
  19. T

    boulter camray

    Thankyou kind sir I am forever in your debt. So dont ask to be repayed lol :lol:
  20. T

    boulter camray

    Hello In the Boulter MI's what are the flue distances in brackets please Thanks Im feeling a bit thick here by the way :oops: Brian