  1. K

    Condensate pipe weeping

    It's a push fit, just pull it off & push back on having first smeared silicone grease or similar around inside of female part. If that fails, pop a hose clip on it.
  2. K

    Ideal C30 combi major leak

    Virtual pint says a rubber seal on plate hex has failed, mains water will then spray everywhere.
  3. K

    Combi Installation advice -

    Make sure you ask installer to put a filling loop downstairs, along with a pressure gauge, so that if system needs a top up, you don't have to climb in the loft.
  4. K

    Worcester Boiler Pressure Help

    Engineer left the flexi attached because we get a million calls a day fro people who, despite being shown, are unable to top up their boilers, if we leave hose on, there's a small chance we can talk people through it over the phone. The reason it should be disconnected is because of water regs...
  5. K

    Rip off Plumber's

    People like this need to taken out and shot, several times. They give honest people like you & I a bad name. I hope she gets her money back
  6. K

    Electrical pipe freezer 25mm MDPE pipe

    Squeeze off tool for me everytime.
  7. K

    Brown water from hot water taps

    I'd love to watch you do that
  8. K

    Soakaway for new Condensate Boiler.

    I'd love to know why a pump "could be bad for the boiler" The pump will only run when the reservoir is full, it takes 10 seconds or so to empty. Best if the soakaway is installed in free draining soil for obv reasons.
  9. K

    Ariston CLAS HE Evo

    Your problem may be caused by several issues, I went to a similar fault yesterday caused by a faulty shower valkve which was allowing cold to water to crossover into the hot side. I was fortunate in that the shower valve had iso valves fitted, I isolated the cold supply to the boiler but water...
  10. K

    shower not working

    Sometimes, local water authorities have to do repairs to water pipes, invariably some debris ends up in the water and clogs the inlet filter on showers especially.
  11. K

    Does this toilet just push on

    Another option would be to use a flexi pan conn, you can attach that, then push the loo back onto the flush pipe.
  12. K

    Power Flush Disaster

    Oh dear, all that expense for one rad.:unsure:
  13. K

    Baxi 401 Back boiler engineer needed nr Worthing

    As above, no reason you shouldn't get another 20yrs out of that boiler.
  14. K

    Ideal Logic Combi 30 boiler

    Why not? Part of an annual service in my book.
  15. K

    Ideal Logic Combi 30 boiler

    Your expansion needs recharging by the sound of it.
  16. K

    What tool do I need.

    I hate those things, I agree with suggestion above, use can usually get a bit of give and the nut will loosen.
  17. K

    Pipe type and can I use a Hep2o or Speedit elbow?

    That looks like Hep pipe 15mm. you can use either make of elbow to repair it.
  18. K

    Difficult pump change

    If you're going to take the cylinder out, I'd reposition the pump at the same time for future ease of access.
  19. K

    Replacing bathroom tap - simple Q!

    Change tap, get rid of pop up plug/waste assembly/ fit new waste.