    Boiler burping noise

    OP said earlier he was getting 28mb at boiler
  2. K

    Question about a single pipe heating system

    Ask yourself if it ever worked properly? If it did, what has changed?
  3. K

    Boiler burping noise

    Seemes bizarre that gas supplier can't adjust meter governor to the standard 21mb (+or-2mb), I'd be complaining to them again if it were me.
  4. K

    Expansion vessel or heat exchanger

    As Terry says, shower valve fault
  5. K

    Gas leak alarm

    Why on earth would she suddenly get a gas leak?
  6. K

    Sudden Cold Water From Combi

    As Madrab says, blocked plate hex.
  7. K

    Pump runs when not calling for hot water - y plan open danfoss system

    Your pump may be wired directly to the boiler, in which case, the fault may lie there.
  8. K

    Help! Bathroom radiator not coming on.

    If you've turned the valve clockwise, you will have turned it off. Some of those valves can be repaired when they leak, if not, you'll have to replace it/them. Have you tried opening it fully? Sometimes they stop leaking when fully open.
  9. K

    Ideal Combi c30 boiler - no hot water

    It won't blow up, it'll just switch itself off.
  10. K

    Ideal Combi c30 boiler - no hot water

    Condi trap is full/blocked
  11. K

    Fitting new float valve

    I rarely come across a float valve that is a different length, has any thing been moved, like a thicker doughnut washer?
  12. K

    Swapping part 1 for part 2 float valve

    Usually, yes, sometimes older models may have a different thread, you,ll soon see when you dismantle it.
  13. K

    Yorkshire fittings advice please.

    Yorkie fittings are twice the price of end feed, but you choice. You only need a clean, dry pipe to make a good joint, and a smear of flux. Always best to wipe off any excess flux before you solder, and always wipe the joint with a damp cloth after soldering to remove any flux residue. There...
  14. K

    Bath panels vs bath tiles

    Panels everytiome for me, did mine 4 yrs ago, and they look just as good today. As Madrab says, worth paying more for hard backed ones, they're very robust.
  15. K

    Boiler increasing pressure with filling loop disconnected, new boiler same problem.

    Turn off the cold water supply to boiler underneath overnight, if the pressure remains constant, then you will almost certainly have a pin holed plate heat exchanger allowing mains cold water to enter heating system.
  16. K

    HIVE receiver light going off and pump staying on.

    As you have a Worcester boiler, it's most likely that the pump is wired directly to the boiler, rather than from the wiring centre. The idea is that the boiler keeps the pump running for some time after firing to dissipate heat, others will correct me, but I think it runs until a certain temp is...
  17. K

    Compression fitting running above switch

    Not ideal, would prefer soldered joint, but there are millions like that
  18. K

    Filling loop

    It forms part of the non return valve inside.
  19. K

    Advice on gas fire, very confused!

    As long as the fire passes a flue flow, and spillage test, no additional ventilation is required, as the heat input is less than 7kw.
  20. K

    Mystery combi boiler issue?

    If the display reads 00 then it hasn't got a call for heating from the themostat?programmer.