  1. K

    What have I done wrong!! any help please

    All sorted. Thank you for all your help. I had the orange wire in the wrong block, it was in with the programmer and boiler wire. Now I've put it in the correct place with the black wire from cylinder stat and blue wire from boiler. All working fine. Thanks again for all your help.
  2. K

    What have I done wrong!! any help please

    How do I check the micro switch is activated?
  3. K

    What have I done wrong!! any help please

    I think the wire is in the correct place. It's gone in the same place as the old came from, I think! What should this orange wire be connected to?
  4. K

    What have I done wrong!! any help please

    I can turn HW off from programmer and the valve moves. It just wont fire up when CH only is selected. CH and HW on together =valve moves, water gets hot and rads heat up. HW only on = valve moves, water gets hot. CH only on = valve moves but boiler wont fire up and no heat to rads. Hope...
  5. K

    What have I done wrong!! any help please

    Hi and thanks, New 3 port valve fitted and wired exactly as the old one was. Now I have the boiler fire up when HW is turned on and plenty of hot water. If I turn HW off and turn on CH the boiler wont fire up at all and remain cold. If HW and CH are on together the rads are getting hot...
  6. K

    What have I done wrong!! any help please

    I think the old valve is faulty because it's fairly corroded and when HW is turned on the upstairs rads also come on and get very hot with the downstairs staying cold. When you say below the level of the valve, how exactly is that done.
  7. K

    What have I done wrong!! any help please

    Hi, I will be attempting to fit a new tower 3 port valve tommorow as a replacement for the old worn out one. This is a like for like exchange. Is there anything I must do, obviously I'll have to drain the system and shut the power but how far do I drain down? I can turn off the main feed and...
  8. K

    advice/help req please

    Hi all, I have independant HW and CH controlls/timer. This can be set to HW only or HW and CH together. The problem is that when the HW only is selected, whether this is on timed or constant, the upstairs rads get red hot but the downstairs rads remain cold. If HW and CH are selected...
  9. K

    2 port motorised valve

    Hi all,, just a quickie. The lever on the valve has resistence in one position and then just flops about from side to side in another position. I geuss this is knackered, am I right or should this do this? Thanks, Dave
  10. K

    myson apollo no hot water.

    The little lever below the valve is just 'flopping' from side to side but if I turn off the power supply and then turn it on again I can hear the motorized valve working. If I move the lever by hand over then it will return to original position. Why is the pipe hot leading to the tank if stuck...
  11. K

    myson apollo no hot water.

    Hi chaps, Myson Apollo Fanfare boiler trouble. Radiaters heat up in all rooms and work fine but no hot water to taps. All pipes are very hot either side of pump and going down to 3 way valve, pipes are still very hot either side of this valve and up to the storage tank. Pipe on top of tank...
  12. K

    Thankyou everyone

    Just like to say thankyou to all the people (namsag, nickso, grahamderek) to name a few who advised and diagnosed my boiler fan problem. Thanks for all your time and knowledge, you people certainly know your stuff. The problem was the fan timer board as most of you all said!! I have now...
  13. K

    namsag or any other help please.

    I cannot get my head around this. Surely if there is 240volts getting to the fan it should spin. Or am I missing the point somewhere???
  14. K

    namsag or any other help please.

    sorry, test 3 is measured from disconnecting the two wires from/at the fan and then testing these two wires indivdualy to earth at the fan end. One wire reads 240volts and the other is near zero. hope this makes sense. test 1 =240volts test2=0volts test 3=240volts on one wire and near zero...
  15. K

    namsag or any other help please.

    Thanks for your replies. You're probably right nickso, but I need to be 100% sure before I go spending. I have tested between the two wires as you ask grahamderek and I'm getting around 10volts.
  16. K

    namsag or any other help please.

    re myson apollo 30/50s boiler fan problem. I have tested the fan wires(the two purple wires connected to fan) again with a multi meter. If I disconnect wires from fan and connect to meter individualy ie +prong on fan wire and negative prong to earth I have 240volts on one wire and near...
  17. K

    myson apollo boiler fan not working, any help please.

    Thanks for your help/advise and time nickso. Dave
  18. K

    myson apollo boiler fan not working, any help please.

    Where can I buy a new fan board from and roughly what's the cost?
  19. K

    myson apollo boiler fan not working, any help please.

    Thanks NICKSO, cant I pull the connector apart male/female? If I could work out how to include a photo of this part on here, would you be able to tell for sure if this is the board that needs replacing? Thanks for your time and help.
  20. K

    myson apollo boiler fan not working, any help please.

    where is the location of the fan board on the myson apollo fanfare boiler. the only board I can find is right underneath in the middle behind a metal plate. This is connected to 6 wires(i think)via a male/female connector. There's not very many components on it. Would this be the fan board?