Search results

  1. P

    Boiler keeps turning on and off, house not getting to temp

    If the rads don't feel like they're getting that hot check what the temperature dial on the boiler is.
  2. P

    2 cold rads downstairs

    What size pipes are feeding the radiators and what size are the radiators.
  3. P

    Remaha Avanta boiler

    Not much people can help when the is a huge lack of info.
  4. P

    Heating pressure?

    1-1.5 bar
  5. P

    Condensing boiler exemption

    Get a drawing up of the layout of your flat and people might be able to help easier.
  6. P

    Fitting shower onto 60mm breeze block wall

    Chase the pipework in the wall for the exposed shower and it will be fine.
  7. P

    Condensing boiler exemption

    What have other people done in the same situation.
  8. P

    Condensing boiler exemption

    All boilers must be condensing unless you can prove it not to be possible, can't renember when it changed though.
  9. P

    Condensing boiler exemption

    I'm pretty sure there are exemptions but they are very hard to qualify for.
  10. P

    COMBUSTION CHAMBER SEAL?

    replace it yourself then but don't come back here saying you've killed your family when it's gone wrong.
  11. P

    COMBUSTION CHAMBER SEAL?

    Replacing the seal means working inside the boiler, so your not even aloud to do that yourself, where abouts are you based?
  12. P

    COMBUSTION CHAMBER SEAL?

    Phone UK a gas safe registerd engineer and he will sort it all out for you.
  13. P

    Plumbing issues - shower pressure low and other issues

    1.6 isn't man enough for 2 showers, I've recently fitted a 3bar pump for 2 showers. Don't pay the bloke anymore either.
  14. P

    Triton Power shower

    Can you here the pump going in the shower while the flow of water is low.
  15. P

    Ensuite - waste and soil connecting under shower tray photos

    Does that soil pipe have any fall on it ?
  16. P

    Bosch pump in my WB 24i junior

    :D :mrgreen: :D :mrgreen: :D
  17. P

    Just had a new boiler installed, is this Flue right?

    That will be there to keep the flue gases far away enough from the vent. Rules and regs change, just because the old one was fine doesn't mean the new one will be the same.
  18. P

    Position of combi boiler to comply with building regs

    I am gas safe indeed, have to renew my courses on the 5th-8th January :( gs number is 17504
  19. P

    Towel radiator

    Your local expert is a bodge
Back