  1. A

    Worcester Bosch 280RSF Problem

    2 faults pressure rising when hot .check the expansion vessel for a pre charge of approx 1 bar...chances are that the precharge has gone and just needs recharging or new pressure vessel fitting. temperature ,renew the central heating temperature thermistor (these commonly go out of range...
  2. A

    hot water being fed into cold water header tank

    dont ever be tempted to block the open vent pipe with anything ..it is an open vent for a reason and that is to stop pressure and allow cold feed from the header tank.. 4 possible reasons for pumping over .. A. pump speed too high try a slower speed B. boiler thermostat too high or out...
  3. A

    baxi barcelona problems

    trobo, where to start ,obviously you are trying to help,a few comments from my 26yrs as a heating engineer. A ...electrics ...you dont test to see if the appliance is electrically safe before working on it...no mention of removing the fuse ? or testing with a multimeter...
  4. A

    Sime combi boiler not firing

    to put you out of your misery the air press switch (aps )is operated by the fan spinning and the venturi in the out let of the fan housing causing a pressure differential across the 2 flexible tubes leading to the aps making the aps move and complete the circuit electrically...therefore before...
  5. A

    Duel flush valve letting by

    probably the water isnt shutting off when it refills this is usually down to muck in the inlet valve.. try checking if its that first before condemning the syphon setup,also lowering the water pressure to the wc helps as well
  6. A

    Help identifying valve and TRVs connected to HW cylinder

    the valve you have is a drayton ravi stat which is going to be at least 15 yrs old . as mentioned b4 these are old fashioned and potentially trouble some due to there being no interlock to the boiler to stop it firing ,,the other component is an AAV (auto air vent ) to stop air trapping.. Due to...
  7. A

    Worcester Combi 280 RSF Heat Exchanger

    combimate cost about £100 plus fitting b4 u ask lol bster ,,, i think from my technical ability i may not be an installation eng nor a service eng .. therefore with out giving my identitiy away i could be technical :-)lol
  8. A

    Worcester Combi 280 RSF Heat Exchanger

    fit a combimate +get it done at same time as heat exchanger
  9. A

    Worcester Combi 280 RSF Heat Exchanger

    2 things to chk,,,,1 is the diverter valve passing to rads when hot water is demanded,with the boiler cold turn on hot tap and run water +chk temp of rad iator flow pipe,,if it gets hot your diverter valve is passing +and will need overhauling and or replacing...2 when hot water drawn off watch...
  10. A

    Potterton Powermax HE85

    i work on both powermax and worcestor i definately prefer powermax,,a damn sight easier to work on ,, and easier to fault find ,, just my opinion zzzzzzzzzzzzzzzzz
  11. A

    Baxi Bermuda problem

    dont most people call them oxypilots.... little hole big bit of dust=no flame=no heat///just my 2pworth
  12. A

    British Gas trainees and wages

    In reply to the original question,I am commencing employment with B.G on 12/2 as a trainee service fitter.The training is 30 weeks duration during which time the wage is £18,700.Upon completion of the training this rises to £21,950. in relation to the above the training seems to be to...