  1. D

    Challenger alarm code reset

    Yes , its in the manual.Its the next bit about resetting customer codes , just follow the instructions.
  2. D

    Optima XM fitting of a new bell box...

    The bellbox comes with a comprehensive installation guide and is compatible with your panel. The 13v + / - terminals are for powered detectors , and the SET terminal is for latching detectors ( it is 13v positive when the system is set , goes 0v when unset).
  3. D

    Accenta G4 Mini Fire Zones

    Yes you can program the zone 5 as a normal alarm zone or as a 24 hr zone , so as an internal alarm is sounded if the door is opened while the system is unset. Have a look at the Texecom Exodus range of smoke / heat detectors. Please seek professional advise if unsure.
  4. D

    Accenta G4 locked out rkp lcd lit no power or day light on

    I would suggest a complete power down , mains and battery, leave for at least 10 secs , then power up mains first.If that doesn't work remove all wiring , replace factory links , then try the default method as shown in the manual , if that fails , then it looks like its replacement panel time...
  5. D

    Manual needed for modern alarms series 1000

    Looks like a 9200 Scantronic. You can get the manuals from ukpanels.
  6. D

    help - Scantronic 9425 problem

    Make sure you let the entry time finish , Scantronics have 2-ply entry sounders , where the internal sounder triggers ( as a pre-warning) then the external sounder follows later.An easier way to test it is to press the PA button. There is also a possibility that the bell has a delay...
  7. D

    Veritas burgler alarm control panel lock down

    You need to repair your sensor , this should allow you to reset the panel with your user code and press reset.
  8. D

    HELP Compact SL

    Your bellbox can operate from its own supply (as you have proved by removing the battery and mains from your panel) or from a switched negative from the panel , this can be simulated by placing the link as instructed .Because your bell sounds when the battery / mains is removed , this proves...
  9. D

    Cable routing

    If its only a short distance , I wouldnt worry about it.You could use screened cable if you want.Have a look at the ACT Meters website , there used to be some articles on measuring and reducing induced AC.
  10. D

    Help with Accenta/Optima alarm Entry/Exit.

    If you have the engineers code , just change the zone that protects the back door to a timed zone (page 34 in the manual). Obviously I don't have knowledge of your property , but its usually best to only have one ex/ent route, and coming in through the back door could be more dangerous ( darker...
  11. D

    HELP Compact SL

    If you place a wire link between A and B of the bell conections (with the wires still in their terminals) then the outside sounder should sound.This should point to the bell and its wiring being o.k. Then its just a matter of finding out why the panel isn't triggering the bell ( either a blown...
  12. D

    Accenta 6 alarm

    The alarm requires defaulting , this will give you a user code with which to control the alarm.It may be wise to replace the back up battery at the same time.
  13. D

    Cost of getting someone out to reset/ add to accenta alarm?

    Because she doesnt have the engineers code...and to set-up a part set would require some reprogramming...using an engineers code.
  14. D

    Cost of getting someone out to reset/ add to accenta alarm?

    Hi , all that is required is a "part set" setting up , so the kitchen would be omitted , and the hallway would change function to ex/ent.As this is an engineer function , you would need the panel defaulting , re-programming and a service (basic test of all functions / detectors and sounders ...
  15. D

    Scantronic 9448+ inputs

    The 9448+ doesnt use resistors, the wiring and diagrams should be virtually identical.
  16. D

    optima g3 alarm panel

    T = tamper return = BT A = 0v = B/S- D = 12v perm = + B/S B = Bell trigger = BA Strobe - = strobe neg trigger = STB sometimes the legends differ from manufacturer ..but the meanings are usually obvious.
  17. D

    Keypads on Accenta G3 appear to be dead

    You will have blown the rkp fuse ( F2 , 1A 20m) always best to remove when testing.There may be a spare in the bottom of the panel.
  18. D

    How do I clear TS690 Fault Code C.TMP 01?

    That message looks like code tamper rkp 1..so it is not recognising the code you are using.If you are sure the code is correct , try 5678 (default user) just incase the panel has defaulted.If the internal siren is still sounding then find its supply wires and snip.
  19. D

    re-tamper circuit

    I presume you mean the Optima alarm panel..the bell tamper wires are T and A .
  20. D

    Omnicron 7000 Panel to Odyssey 1E Bell Box

    Yes , just leave the jumpers as it came out of the box..battery on , SAB.