    Worcester 40 CDi - Fault

    WB do service booklets for the CDi range old and new, you can either download them from their website or order them from WB literature line. I will dig out the part numbers for you when I get minute as without them you are liable to end up with a set of instructions for danesmoor 18/25. I...
  2. A

    Does copper pipe have any value ?

    I used to clean all fittings off my pipe, but as long as the brass is off our scrappie gives you £3/kg at the mo.
  3. A

    Worcester 40 CDi - Fault

    That symbol is the syphon-fill Tony. When the boiler fires from new it first goes through an 8 minute air purge as there is no AAV on the heat exchanger. This is a one time only function however it can be turned on in service mode if required. After that the boiler then goes into syphon-fill...
  4. A

    Worcester 40 CDi - Fault

    The fault you are describing is the gradiant limitation kicking in, boiler flow temp is rising to quickly. How is your system set up? is the heating split into zones? is it two or three port zone valves that are used? Is there a system by-pass fitted?
  5. A

    Please Help! Worcester Bosch Greenstar Cdi not working

    Instructions for your stat/reciver are here http://www.salus-tech.com/manuals/RT500RF.pdf This will show you how to flip off the cover to check if LEDs are lit.
  6. A

    Please Help! Worcester Bosch Greenstar Cdi not working

    As gg has said when you reset the boiler it will go into hot water pre heat function this will fire once every 20 minutes. Does your boiler have a built in timer? or an external timer? are they calling for heat? (forget this just noticed it's a programable stat) if no fault code is showing...
  7. A

    Which Combi to install?

    If your gas pipe is 15mm it will need upgraded regardless a 15mm supply will not do a 24KW boiler. 5-7 years :lol: A well installed, well maintained combi (even a cheaper brand) will last for 10-15 years no problem. Yer man sounds like a right cowboy by the way. Like Tony said ask 10...
  8. A

    Which Combi to install?

    Ooop's wrong thread :lol:
  9. Untitled

    Untitled

  10. Untitled

    Untitled

  11. Stuff

    Stuff

  12. A

    How to re-prime Worcester Danesmoor 20/25 oil system?

    Regardless of the solenoid being faulty the pump should still pull oil in and you should have been able to bleed it no problem. The pump builds fuel pressure before the solenoid opens so should still have bled. If the motors turning sounds like the pumps goosed or it may be completly dry in...
  13. A

    Possible problem with Danfoss RX1?

    When you turn the stat down do the rads keep heating? And is the red light on the RX1 on?
  14. A

    worcester 440cdi constantly on

    Yep blue light is the power indicator. If the boiler is running with no call for heat it may be replenishing the heat store, it shouldn't be on for too long though. A few minutes or 5-10 if hot water had been drawn.
  15. A

    New Heating System does not work!!!

    Do these things not modulate?
  16. A

    greenstar 30cdi stuck in purge mode?

    My fault I've revived a few old threads today :lol:
  17. A

    How to re-prime Worcester Danesmoor 20/25 oil system?

    If you visit the worcester website http://www.worcester-bosch.co.uk/installer/products/oil-boilers/greenstar-camray-1825/literature download the installation instructions (second link down) and an explanation of how to prime a tiger loop is on page 36
  18. A

    How to re-prime Worcester Danesmoor 20/25 oil system?

    A tiger loop is a deaeration device, you are right in that the oil pump is what lifts the oil. When the pump switches off the theory is that the oil will flow back to the tank allowing air into the system which the tiger loop ten eliminates. I dont fit them, I prefer to fit a NRV although...
  19. A

    greenstar 30cdi stuck in purge mode?

    I always put these in service mode for service and during commissioning to get the hw flow rate from the turbine, I have never had one stick. Yet :lol: