  1. M

    potterton profile fan runs but dont fire

    you could link it out but you can also check switch electrically without power on using multimeter. Check if you are getting continuity between common and normally open when you make switch by sucking and pinching
  2. M

    potterton profile fan runs but dont fire

    quickly check that the o heat stat under boiler hasnt tripped first
  3. M

    Boiler Pressure keeps dropping

    sounds like expansion vessel issue to me, lots of threads about fixing this are on this site mate
  4. M

    Boiler not switching off

    surely it must be going off when the overheat stat trips, otherwise it would just boil, turn into steam and burst heat exchanger
  5. M

    Europa 24 struggling to ignite.

    its pretty hard to determine what is wrong with it without standing in front of it. Sounds like there is possibly more than one fault with it. As you say it could be the APS ,sometimes these get stuck in the no prove position or the diaphragm part bursts,you could use a multimeter on this with...
  6. M

    vent radiator

    that rad may be just slightly higher than the rest therefore the air already in the system is being depositited in this rad. Another is corrosion in pipework causing (gassing) try lighting vent while you are bleeding the rad, this will tell you if this is the case or not, dont worry you wont...
  7. M

    Alpha CB24 Problems.

    i have just noticed you have wrote constantly but is that constantly when heating is on or just constantly and is only hot when the heating is on
  8. M

    Europa 24 struggling to ignite.

    check the condition of the flame sensing electrode and if in doubt give it a rub with some steel wool and check the gap between it and the burner is around the thickness of a pound coin
  9. M

    Alpha CB24 Problems.

    sounds like the expansion vessel regarding the water being discharged from the blow off pipe, i take it the pressure on the front panel is at 3 when this is happening. there is plenty of info on this site regarding recharging an expansion vessel but if you are toiling i will write out a...
  10. M

    is it a leak or not a leak

    sounds like auto air vent is passing water slightly, go to local merchants and get a new one, fitting should be easy as highest point of system so no big drain down required, just drain boiler at prv or boiler drain cock to release some pressure
  11. M

    boiler problem

    its sounds like kettling but as said , need more info
  12. M

    Alpha CB28, cold water

    i would check the flow switch first, cheap and easy to change. These boilers are quite pants, every one ive worked on needed expansion vessel recharged
  13. M

    My new gas valve

    sounds like the overheat interupter linked to the thermocouple at gas valve end, you could test this by linking it out with wire, dont give yourself a shock though
  14. M

    My new gas valve

    is this a vokera, what make and model
  15. M

    Combi boiler problem

    Thermistors :- With the power off unplug the connector and test resistance is 10k ohms at 25°C If you have a decent multimeter you could try this Could be a few things causing possibly gas valve or modureg issue as well but you would need a dog card for that
  16. M

    Do I need a room thermostat?

    didnt know that, to stray off subject slightly, what happens in a situation where part L has not been followed correctly, still know some guys fitting non condensing combis as they are 10 a penny now.
  17. M

    Alpha CB24X Loss Of Pressure

    take off 2 screws and fold down front panel. Drain boiler using prv, (red valve, turn). go to back of boiler next to flue and take off the 4 screws at top,and remove metal plate, this gives you access to the exp vessel. Take off cap of schraeder valve and use a bike pump to recharge vessel...
  18. M

    Do I need a room thermostat?

    take trv off of hallway rad and get monkeyboy back to fit room stat as you need a control to switch the boiler off electrically and not just have boiler stat /potentiometer cycling off/on all the time
  19. M

    Vokera linea 28

    take casing off and drain boiler through prv, (red , with 3 bar written on it) Take the flexi pipe that joins the vessel to pump housing prv area and clean, will be full of black gung. (use long thin screwdriver) Cover pcb with dust sheet when taking pipe off. Reconnect and then use an air...
  20. M

    Hot water boiling over

    also, check that there is a bypass fitted between flow and return before the zone valves, this is just an interconnecting pipe between the pipes to allow the water to circulate when controls have been satisfied