    Hot water boiling over

    sounds like the expansion pipe has not been moved with the boiler/pump and is probably pumping over all the time. check to see if the ex pipe is before or after ther pump. Also, constant hot water in header tank could soften /loosen plastic fitting on tank so beware of leaks if this does not...
  2. M

    potterton profile 60f regular ,open vented boiler

    forgot to say what the boiler was doing. Nothing basically, all external controls working, pump etc but nothing at boiler apart from the readings above
  3. M

    potterton profile 60f regular ,open vented boiler

    working blind, no instructions and even diagram on underside panel torn/missing. getting 240v live and switch live at boiler, 240v either side of oheat stat, i think it requires new pcb, anyone else?
  4. M

    Central heating problem

    ok cheers mate, that rules that out
  5. M

    Central heating problem

    it could be the pump if it does not have a plate heat exchanger, cant remember if this model has a twin pass ex, if it has ,most of these types only use the pump on ch, any idea dave?
  6. M

    Baxi 105e - Fault on fan or flue?

    try cleaning the venturis, these are on the fan area and are connected to the air pressure switch by the silicone tubes, even the slightest bit of dirt in these metal tubes prevents the switch from being made. you may have to slide the fan assy out to get to these.
  7. M

    How do I let water into my vokera combi boiler

    yep, take the black lever off with pozi screwdriver and turn internal part with pair of pump grip pliers, let us know how you get on mate
  8. M

    How do I let water into my vokera combi boiler

    try underneath the boiler, the black knob with close and open, once you fill it up it should run, the low water pressure switch is keeping it shut off at the moment
  9. M

    How do I let water into my vokera combi boiler

    there must be another lever or tap to turn either at the boiler or on other end of the filling loop
  10. M

    How do I let water into my vokera combi boiler

    you need to look for a flexi pipe which is the filling loop and turn the black lever or levers on it in line with the pipe and watch the gauge rise to 1.5 then turn it off
  11. M

    Worcester bosch Greenstar 30CDi

    im right though, better late than never
  12. M

    Worcester bosch Greenstar 30CDi

    just changing the code plug on the pcb to a 40 would have solved this without changing the boiler methinks