  1. S

    Biasi Combi Boiler question - London / Essex border

    has he never heard of instructions ? ie the list of parts that would tell him exactly which fan and part number of it?
  2. S

    Any Good Alpha Guys About?

    the fault might only show on HW as fan is working harder! If it is easy enough to take flue apart i would make sure that all seals are correct! and check instructions to make sure that flue has correct size of restrictor ring! i am not an Alpha expert but as i said i have seen this...
  3. S

    Ravenheat RSF 84 - thermistor!?!

    1st thing i would look at on ur boiler is fan/flue.
  4. S

    Any Good Alpha Guys About?

    is it dropping out on the APS? if it is fairly new make sure the flue is 100% been to loads of new installs that drop out the APS because flue seals have been incorrectly pushed together
  5. S

    Ravenheat RSF 84 - thermistor!?!

    To check fan you would need to break chamber seals, so if ur not corgi i wouldnt! Does the boiler not even try to fire on HW?
  6. S

    External drain join/seal leaking - What to use to seal it ??

    Are you sure it isnt a blocked drain? Seen that before and the whole void underneath house had about 3foot of water.(dunno how people in house didnt smell it)
  7. S

    Ravenheat RSF 84 - thermistor!?!

    Thermistor wouldnt stop it from lighting. if it was thermistor it would light up then shut off. Possible fault on that boiler is fan which i have had before - heatin worked fine but fan wouldn't go to full speed when calling for hot water.
  8. S

    Radiators heating up when they should'nt

    Sounds like ur CH 2port valve is stickin open. u need full new one
  9. S

    To flush or not to flush...

    If are are sayin you feeder tank is full of sludge - when you drain heating down all that sludge is just going to clogg up your 10mm pipe! If i were you i wouldnt bother flushing it out but eventually you prob will need a power flush.
  10. S

    Pressure/Flowrate

    a quick test - this would let you get an idea of how good ur pressure is place ur hand under the tap sealing the hole where water comes out, if you are able to stop the water without getting spray everywhere then ur pressure is poor , if u find it hard to stop water spraying everywhere...
  11. S

    Hot water problem with Ravenheat combi

    Is ur burner shutting down intermitantly when you are running HW? Or does burner stay on ? Possible cause is CH sensor (more than likely if older model with WET sensor)
  12. S

    capping off a soil pipe

    you can buy blank caps for 4inch pipe, is it not possible just to put rumble bag tied over the open pipe?( if it is just to stop the smell) u would need blanks if water would be flowing past the open ends
  13. S

    Ravenheat combi CCSI 85 Fires up then stops every 2 min

    Remember the if its the fan mod - Boiler only shuts ON/OFF on CH If it works fine on HW prob not fan mob pcb
  14. S

    ravenheat

    I thought fan runs at slow speed with pilot on?
  15. S

    zoning

    How big is ur house? how many rads ? would u be able to run pipes staight from boiler through all floors? how many HW draw off points? where u puttin boiler?
  16. S

    leaking radiator

    drain it remove nuts and PTFE tape the threads
  17. S

    BYPASS

    ravenheat 150 low nox
  18. S

    BYPASS

    Just with the automatic bypass valves i take it that the higher the number the greater the flow of water through it? haha silly Q but just want to make sure! the boiler is only a couple of weeks old and installer isnt going back so some how or other i have been roped into this job. system...
  19. S

    Automatic BYpass

    I have a problem system that constantly trips every now and again on overheat, It has an automatic bypass on it and i want to set it so that i have a min of 11 l/min goin through it(as per manufactor instructions) can someone tell me what resistance to put on the bypass and how to set it...