    Water leak from chimney?

    Provided there are sockers at the side of the chimney the step flashing will be ok . I would look to plugging it properly , maybe get some hall clips the lead mate , it's not very though as it is . The tray will be the issue . , if it's not turned up on the inner sides and back you could get...
  2. D

    Water leak from chimney?

    Strictly speaking the trays are to high . Top one by one course lower one by two courses . Can only assume the lower one is turned up inside the loft area ? You could increase the size of the front and rear flashings so they cover the exposed bricks . Check inside they are turned up .
  3. D

    Gap at top of bonding gutter

    Maybe they used this
  4. D

    How bad is our new roof? Photos in post

    Expensive mistake ..
  5. D

    Tiles swapping around on roof but don't want to damage felt

    they should have used more than one pallet at a time.. it says that on the paperwork.
  6. D

    How bad is our new roof? Photos in post

    Looks like tlx gold fitted incorrectly. You should not see the black lap . It has a top and bottom , so it's wrong . Send an image to tlx support and ask if it's correct ... It's not. Dry valley , not for me anyway .
  7. D

    Ongoing leak through cavity from soffit and weatherboard interface

    Shouldn't need a cavity tray and it'll make no difference It looks like it's showing more on the inner skin. Battens wet ...difficult to see exactly headlaps look skimpy . Id revisit the roof . Check gauges on each course check the underlay is correctly fitted,
  8. D

    Gauge / headlap old double roman clay tiles on barn roof

    The headlap on clay double Romans is set in stone. It's not adjustable
  9. D

    Extractor fan tile vent ducting squashed into eaves

    Rectangular extractor duct. I've even seen them on amaz
  10. D

    Lead Flashing Repair

    It's an aged stress fracture cause by incorrect fitting . It's not an over bossed split
  11. D

    Stains/water leak on ceiling

    Roof pitch and tile gauge look iffy
  12. D

    Extractor fan tile vent ducting squashed into eaves

    You can get rectangular adapters .for tight spaces
  13. D

    Seal above canopy

    Concrete panels prefab
  14. D

    Lead Flashing Repair

    As stated above Or fitted under it . It's nothing the roofer done . It's due to how the lead was fitted originally .could be low code too.
  15. D

    Roof battens not level across valley

    Just to add , use of lead or grp isn't always acceptable over valley tiles . Fwiw 40 /70 is doable .
  16. D

    Seal above canopy

    That's good!
  17. D

    Dry ridge system for roof to flat dormer?

    Looks like they tilted the ridge over to get over the flat roof .. Cra ppy idea .without seeing more of what you have there it's all guess work . Ridge over flat roof would need one side cut off to enable the main ridge to sit central , even if you cut the ridges as I said a dry fix could still...
  18. D

    Broken wet verge

    Get a couple of bags of remix . Clear out all the old mortar and re bed the verge , use a screw and not a nail for added security .
  19. D

    Seal above canopy

    Is this a rema house ? If so flash band is your best bet