    soil pipe not in the right position for new toilets

    penwen, i meant something like this, regards chrisey http://www.plumbtec.com.au/ren_guide/toilet_suites.htm
  2. C

    soil pipe not in the right position for new toilets

    As Nige F says the offset multiquick is your best bet. Unless you can find a concealed outlet pan which drops directly over the soil pipe (cant think of the name of them now) regards chrisey
  3. C

    soil pipe not in the right position for new toilets

    Could you show a photo of the setup, and dimensions from the back wall to the back of the soil pipe outlet. regards chrisey
  4. C

    Recommend me a boiler ?

    Worcester, Alpha, vailiant, Top three performers give the least problems chrisey.
  5. C

    Worcester cdi DT20 controlls

    YES it works as a preheater. its a shame worcester dont give explanations about there controls on there site regards chrisey
  6. C

    hosepipe to supply electric shower

    I think he should use a Bibcock and run a hot water supply outside, one with a non return valve though, Would save the cost of a spark and an electric shower. :lol: :lol: :roll: :roll: regards chrisey
  7. C

    Bath dropping

    There are several reasons why this kind of thing happens. 1. Is the floor stable or does it deflect. When fitting a bath its always a good idea to use some type of bearers under the legs (4x1 25mmx100mm)2. Has the bath got a bonded baseboard,( By this I mean the fibreglass matting completely...
  8. C

    Worcester 28si 2 pressure gauge

    Many thanks Craig, to many boilers about with to many faults. Cheers chrisey
  9. C

    Worcester 28si 2 pressure gauge

    Boiler pressure gauge not working even though presurised and fires up, any one had a faulty gauge on one of these or could there be something else causing it not to work. regards chrisey
  10. C

    Worcester 35 CDi pressure drop

    Heating enginreers/corgi reg installers on this forum should not be giving information to the layperson to look in boilers for leaks etc. You should all know the consequences involved. Keep it simple Regards chrisey
  11. C

    Water does not heatup, radiators seem fine

    Yes Dan seems like the valve, unless there is two pumps on the system!! cheers chrisey
  12. C

    potterton suprima 80 question , does green light come on for

    We seem to have 2 posts here on the same sublect. Can the moderators remove one please. Regards chrisey
  13. C

    Low inlet gas pressure - Worcester Greenstar 42CDI bolier

    I agree with the last post, Someone with some common sense, chrisey
  14. C

    Water does not heatup, radiators seem fine

    Which boiler are we talking about here, If you can tell us make and model im sure someone on here will be able to help. Regards chrisey
  15. C

    potterton suprima 80 question , does green light come on for

    is it a potterton programmer by any chance , with the sliders for HW & HTG, If so its probably faulty. regards chrisey.
  16. C

    New gas boiler in greenhouse

    YES Dan lol chrisey
  17. C

    New gas boiler in greenhouse

    NOT an ideal place to site a boiler in a greenhouse because the temperatures could be in excess of 100deg. The boiler needs a good circulation of air. There must be plenty of other places in the property a lot more suitable. Regards chrisey
  18. C

    Low inlet gas pressure - Worcester Greenstar 42CDI bolier

    If you have a cooker and a gas fire at the property and your supply pipe is longer than approx 6Mtrs excluding bends in 22mm it is too small for this boiler to work properly. The boiler takes 4.4M3/h at max working pressure so a min 28mm pipe over more than approx 6mtrs would be required. You...
  19. C

    New Bathroom

    You can use a speedfit tee piece and insert a 15mm brass dp in the branch. (always a good idea to have a dp) then continue with your speedfit as you suggested. Dont forget the plastic inserts when using speedfit to speedfit, Regards chrisey
  20. C

    cold radiators

    If you have a drain point downstairs on a radiator, connect a hose and drain off leaving the system refilling, this might help to shift any air. Failing that you could leave the hose connected turn off the drain point, connect the hose to an outside tap open the tap and the drain point CAREFULLY...