Search results

  1. J

    expansion vessel

    vessel, 50-100 quid depending on boiler fitting, 1-2 hours labour.
  2. J

    expansion vessel

    You'd need to take it off the wall but unless your gas safe registered your goosed as would involve "breaking" a gas connection. Even if there is enough room to remove it from above the boiler you may need to disconnect the flue bend, either way you need a registered installer.
  3. J

    thermostatic valve

    Is your system pressurized or does it have a F & E Tank?
  4. J

    Vokera Combi Compact 28

    Its after the heating's been on all night. Will check the thermistor and venturi tomorrow and yea I'm Gas Safe registered, handy wee forum this, just waiting on the combustion chamber access, is this forum on the go yet mate as would have posted there if had access :) Cheers
  5. J

    Vokera Combi Compact 28

    Anyone had any bother with these? Boiler goes to lockout and the customer has to reset, usually in morning. I think it could be the CH Thermistor but just thought i'd ask here before I head to it tomorrow night. IIRC it could be thermistor, gas valve or PCB? Anyone encountered this...
  6. J

    Vokera Linea 24 fault code 01 causing cold water to run.

    Agree with bingo, always check/replace the cheapest parts first, the thermistors are about a tenner.
  7. J

    ARISTON MICROCOMBI 23 MFFI

    Aye the PCB was different, but got the part number from ariston themselves. PCB 65100248, the pcb works when I disconnect the flow switch, I'm hoping zk's post is right in that it needs a new updated one, hopefully ariston will be able to tell me.
  8. J

    ARISTON MICROCOMBI 23 MFFI

    Different model. http://www.ariston.co.uk/uploads/doc47cd559f93b96.pdf
  9. J

    Central Heating will not turn off

    Could be the microswitch is jammed in the on position in the CH motorized valve, turning off prog etc will have no effect, the only way you can get the boiler to stop firing is turning off the spur unit. If you are confident with electrics, switch off the spur unit, open the wring center and...
  10. J

    Worcester 24CDi combi boiler pressure gauge

    These are a bugger, why a boiler manufacturer makes as key! which is often discarded or lost is beyond me, the grey knob is a pain as well and often breaks, sorry not helping, just read this and fancied a rant lol
  11. J

    One Radiator Cold. All others are off, and system is newish?

    Take a look here >> http://www.gasapplianceguide.co.uk/Boilermate%20BP.htm See if there is an expansion pipe over the F&E tank It may be that you have a pressuzized system and you need to pressurize it, with the braded hose!
  12. J

    ARISTON MICROCOMBI 23 MFFI

    Thanks! Is this on the new board mate? Would it stop the board from working when the above is connected? The one/off is a push button on this boiler. The board on light only comes on when I hae the flow switch disconnected.
  13. J

    Condensing boiler drain query

    I've fitted a unica, decent boiler and never heard of any complaints, you can put the condensate into the downpipe, or if thats gonna be a struggle could you not install a soakaway? Make sure thou you increase the condensate to 35mm (1 1/4) and lag well for freezing purposes. Why not take a...
  14. J

    ARISTON MICROCOMBI 23 MFFI

    Thanks i've checked within the boiler, had every component disconnected/reconnected to try and determine the problem lol. Within the boiler its clean and dry.
  15. J

    ARISTON MICROCOMBI 23 MFFI

    Cheers for that mate, will do, nasty boilers these lol!
  16. J

    ARISTON MICROCOMBI 23 MFFI

    Hi, Wonder if anyone can help. I've had a job that I went too where the PCB was burn't out on a ARISTON MICROCOMBI 23 MFFI and not working. It was burn't underneath at the capacitor. I've fitted a new pcb board (part number: 65100248) but now after fitting it the power light on boiler...