  1. G

    Towel rail question

    Just leave it on it is a negligible extra cost and helps stops condensation etc in the bathroom
  2. G

    Drops from bottom of radiators

    use gas ptfe and dont worry about overtightening you wont
  3. G

    Thermister issue?

    usual reason for luke warm rads and cycling every few minutes is a slight blockage in a gauze filter in the return isolation valve it can also be caused with a sticking divertor valve .
  4. G

    Thermister issue?

    ITS not the thermistor sensor then as the main sensor initially controls both . .It will be a case of waiting to see if it does it again then investigate further
  5. G

    Thermister issue?

    my 105 is 23 years old now it is one of the most bullet proof combi`s out there and have loads on books around the 20 year old mark still going strong so he is giving you good advice. Nope its not a troublesome job it can be changed for the latest baxi purely by using 5 sockets /same flue hole...
  6. G

    Who Needs DIY Bodges

    on a council instal no chance
  7. G

    Water valves under boiler - Baxi 800 - identify...

    balancing on a condense boiler is actually around 20 degrees which on majority of existing installations is more or less impossible to reach even 12 degrees can be a struggle at times
  8. G

    Who Needs DIY Bodges

    The one in my photo pipes were put in around early 80`s the pic was took earlier this year when the damp patch started to show on the ceiling . But we were fixing leaks like that on same estate from early 90`s so that one lasted well
  9. G

    Water valves under boiler - Baxi 800 - identify...

    the lever indicated by your arrow 2nd from right
  10. G

    Replacing ST699 with ST9400C

    https://www.free-instruction-manuals.com/pdf/pa_458238.pdf
  11. G

    Water valves under boiler - Baxi 800 - identify...

    Yellow is the gas so no need to touchit to re pressure the boiler You just pull the green lever down
  12. G

    Who Needs DIY Bodges

    This is why copper needs protecting on stell beams
  13. G

    Obsolete gas valve

    yeah also use the 384345 gc number in parts list
  14. G

    How to unscrew this kind of tap?

    Yeah and possibly crack it
  15. G

    HW/CH Noise

    Some boilers have an in built timer on the pcb that starts the pump up for a short period every 24 hours to make sure it doesnt stick They also have an in built frost that that would kick in if temp drps below 5 degrees but still too warm for that and you would feel heat in the pipes
  16. G

    Obsolete gas valve

    this place is saying they have a new one . https://www.gmsspares.com/product/gas-valves-s1008/ideal-gas-valve-rc3-8-sit-0680-009-i0004050/I0004050 Although it says ideal it is a Sit gas valve
  17. G

    Obsolete gas valve

    https://www.ebay.co.uk/itm/365939217583?var=0&mkevt=1&mkcid=1&mkrid=710-53481-19255-0&campid=5338749401&toolid=20006&_ul=GB&customid=CjwKCAjw04HIBhB8EiwA8jGNbc894rLgUUgxI2nY3Xeq3jjf630qCyxaPNX39s4m2PUz-b6hm0pwQBoCCfYQAvD_BwE|0AAAAADihhqV6RFPf7TWB26VKuMQCX-opR|CkwKCAjwsPzHBhAfEjwA_SWgPv2KtS91Bq0cv...
  18. G

    Obsolete gas valve

    https://www.ebay.co.uk/itm/336178554929?chn=ps&_ul=GB&norover=1&mkevt=1&mkrid=710-134428-41853-0&mkcid=2&mkscid=101&itemid=336178554929&targetid=2361039923645&device=c&mktype=pla&googleloc=9046196&poi=&campaignid=21697381820&mkgroupid=170109506289&rlsatarget=pla-2361039923645&abcId=10027101&merch...
  19. G

    How to unscrew this kind of tap?

    get someone to hold the tap
  20. G

    If not a gas leak, why the smell of sulphur "rotten eggs" in kitchen?

    People can smell certain stuff differently . Just because you have turned gas off doesnt mean there is not a leak before the valve It is completely free to call out the emergency service and they certainly do not mind false alarms so give them a call to rule out it being a gas leak 0800 111 999