    hi, sparks - possibly although never tried it before (my understanding says all neut tied together at switch in bloc?) and actually if this was the case could a 2 gang switch be used and loop from live to second gang for a mirror light? if however not poss is original idea ok going into...
  2. E

    wall lights

    removing ceiling light and replacing with 2x wall lights operated by one switch and need little advise: will have 4 cables to terminate at light one : line in / line out / switch / feed for second wall light. cable is 1.5mm originaly planned on a rose to wall but now thinking space would...
  3. E

    wall lights

    removing ceiling light and replacing with 2x wall lights operated by one switch and need little advise: will have 4 cables to terminate at light one : line in / line out / switch / feed for second wall light. cable is 1.5mm originaly planned on a rose to wall but now thinking space would...
  4. E

    How to become an electrician

    onto 3rd year 2330 now did 17th and pat a while ago, start 2391 in sept and cosidering carrying on with hnc next year and im 38. you could always do a one week domestic installer followed by partp for quick entry, but dont think that is best route. (quick note, if you are in reciept of...
  5. E

    another calc query for the experts

    dont think i would of survived through college as long - learn more through this forum than from lecturers - slowly and surely getting there though - many thnxs
  6. E

    another calc query for the experts

    you fixed it again :) took a while but started with fuses as sugested and can see where its leading now - :)
  7. E

    another calc query for the experts

    thats great (yet again spark) but how is this compared to time/current charachteristic charts? ie: notes from practical guide book: once zs established divide by voltage for fault current. apply this calc to time/current graph to determine actual disco time for circuit. 60898 6a...
  8. E

    another calc query for the experts

    sorry to be a pain: measured zs on lighting circuit of 0.95ohms max zs for 6a breaker in regs is = 7.67ohms do these figures sound correct (only on a test board so no long runs etc) then divided volt by zs for a fault current = came up with 242? not sure how this is compared to...
  9. E

    Controlling a double socket?

    what about clip roud ear - worked on me :(
  10. E

    Is this legal under part P?

    actually just got mine off fleabay - never used £400 very pleased. yours smug :)
  11. E

    rcd operation calcs

    oh i see so the calcs for breakers take presedence - thanks
  12. E

    Detailed quotation

    wouldnt it of made more sense to get breakdown before work was completed?
  13. E

    rcd operation calcs

    oh yes so it is - lol wasnt expressing 30ma as 0.03 silly one more thing though, wouldnt these values for disconection be hard NOT to meet ?
  14. E

    rcd operation calcs

    bs7671 states given values for rcd operation: 30ma maximum Ra 1667 and states formula Ra Idelta n< 50 can someone explain this calculation cant seem to get the formula?
  15. E

    Megger mft help

    thanks gary (had to turn electric back on again lol) think i got it now non trip and 3 leads for rcd side hi settings and two leads for non rcd actually getting readings now and kettle stays on - thanks v much :)
  16. E

    Megger mft help

    yeah the no trip is giving the error (why?) just found hi setting will give you ohms for zs and pfc gives ka for fault does this require 3 leads or can it be done with 2? circuits are rcd protected
  17. E

    Megger mft help

    its 1552 - just cant see where im going wrong
  18. E

    Megger mft help

    been practising testing on a dummy board and all tests work out fine until: measuring ze efli pfc on all these tests MFT displays voltage but then get a TRP message in display - figure im doing something wrong with the procedure any ideas what?
  19. E

    MCB's Protecting Spur

    but thats aspur still surely ( need ban or sparks me think)
  20. E

    MCB's Protecting Spur

    shouldnt a spur only supply 13a outlet? 2 16a mcb will allow 32a through single 2.5? sure its non-notifiable?