Search results

  1. ServiceNumpty

    Domestic Plumber Jobs

    You might be asked if you're able to plaster and tile.
  2. ServiceNumpty

    Water pipes in PIR insulated plasterboard

    Run the pipework in 10mm to each rad from a manifold, then the 15mm dab will be more than enough. Remember foil tape over the pipework to help you locate them afterwords.
  3. ServiceNumpty

    Pressure issue with Viessmann Vitodens 100 Boiler

    Filling Loop and pressure gauge may be in the airing cupboard.
  4. ServiceNumpty

    Vaillant Ecotec pro 28 Help with use / diagnosis please.

    If your plate heat exchanger was passing you wold have a constant 3 bar pressure showing on your gauge and the PRV constantly passing.
  5. ServiceNumpty

    Conventional to combi conversion. Inlet size reassurance.

    I thought that looked like 1/2", with a 1/2 male iron to 15mm compression elbow with a copper feed of it. Or do my eyes deceive me.
  6. ServiceNumpty

    Tried everything - rad problems downstairs

    As you have a 3 port valve, close the wheel head bypass and see what happens.
  7. ServiceNumpty

    contract of employment,terms and conditions?

    I'm still staggered in this day and age, that no paperwork is issued when quoting. What does the quote stipulate, brand, size, location, additional options, warranty. I'm sorry but if someone just rang me with a price and didn't have decency to put something in writing so ALL parties are covered...
  8. ServiceNumpty

    Boiler advice needed Baxi Duo Tec & Wireless thermostat

    The Duotecs do have quite a large lag between when the demand is activated and the boiler firing up. And then you have the post fan purge. The radiators won't generally be hot to give you a room temperature of 17.5 degrees. You/The Installer can change some parameters on that rf stat.
  9. ServiceNumpty

    wet underfloor heating system insulation question

    I'm confused, there are systems out there that have preformed insulation panels, and spreader plates. Is yours for upstairs or downstairs.
  10. ServiceNumpty

    One pipe system

    2K for a full heating :shock: Hmmmmmmm
  11. ServiceNumpty

    Combi boiler problems: What are your opinions please?

    Isn't there a link on these that has to be removed if the roomstat is connected into the low voltage side, or am I talking out of my arris.
  12. ServiceNumpty

    WB Greenstar 30CDi: Turbine adaptor dripped, Diverter Motor

    Worcester Bosch have now fitted a nice green funnel on the cdi classics, to bypass that issue, but for some unknown reason have not fitted them to the compact range.
  13. ServiceNumpty

    Advice please on some plumbing work done.

    Moral of the story - don't do any work on the 'smaller' type jobs that customers think will only take 5 mins as they can and normally bite you on the ass. If you do it in minutes and charge £50 your ripping someone off, if it takes you 4 hours and charge £270 your ripping someone off. I love...
  14. ServiceNumpty

    Am I being harsh on this plumber?

    Most experienced installers understand that an Ideal Classic won't have pump overrun nor a permanent Live, and this is normally explained at the quote stage that a separate cable may have to be run. The other option is to run a 4/5 core cable outside in conduit into the roof space and back into...
  15. ServiceNumpty

    Danfoss Programmers

    The tp9000 is a hard wired programmable room thermostat with it's own hard wired sensor for heating as well as acting like a normal programmer for hot water. Why don't you just replace the FP715 with an identical one. Lots of cheap ones on ebay.
  16. ServiceNumpty

    Hot Water system suggestions

    Many Possibilities. Heatrae Sadia Electric Boiler & small unvented cylinder Electric Combi Boiler Air to Water Heatpump with a small unvented cylinder Electric UFH with an immersion fed small unvented cylinder. All depends on budget and current incoming supply.
  17. ServiceNumpty

    Boiler/heating issues

    Check the pressure relief valve isn't spewing water outside. Outside just below the boiler there should be a stub of copper pipe, if this is dripping that is your problem.
  18. ServiceNumpty

    Cheap Way To Heat Barn Conversion?

    If sized correctly, Heatpumps are a good alternative. Went to do a 6 monthly check last week on one we fitted. The elderly customer is over the moon with how it's performed she mentioned the house has never been as warm, and in the years she lived there, she had oil, lpg and we removed a solid...
  19. ServiceNumpty

    Plumbers done a runner!

    Whereabouts are you in Notts, I'm in Mansfield, so if local and you're not in a rush I can pop over and have a quick gander. Mike email: [email protected]