hi
is this rad a recent addition? or been there a while? could it be sludged up?have you tried pulling water through each valve, what was the flow like through each?
try turning some of the other rads off at the wheelhead/trv end and see if the cold rad starts to warm. if it gets hot turn the others back on and see if the cold rad stays hot. if not possible blockage in valves/pipes/ rad? or rad being starved
try and ensure its completely free, and then either upgrade to 1.25/ 1.5 or make sure its well lagged if leaving the overflow. although with this very cold snap i,ve been to some where even 2 inch has been frozen!
is the noise as its shutting down like a gurgling noise? then its the condense not getting away from the trap in the boiler. the pipe outside what diameter? is it lagged if its overflow? but if the noise is a clanging/banging sound then the waters not getting away from the boiler. try undoing...
yes i think ur right ben. seeing as they worked fine for 2/3 years, im leaning towards blockage somewhere on the return drops to each rad. the inside bore of the plastic 10 mms are tiny- it wouldnt take much to block 1 of those, i doubt if it was cleansed properly on the first fix and if it...
there are 11 rads on the system, 3 are always off on the trv,s 3 ive got problems with and the other 5 are fine. one thing i have noticed is that when ive got the problem 3 on only, is that the boiler cycles often as though its a circulation problem which leads me to think there is a blockage on...
hi ben
yes ive cranked the upstairs lockshields down to a quarter turn open and some of the downstairs rads shes got turned off on the trvs anyway, so its not a balancing problem. any more ideas?. its strange cos i can pull decent hot water thru each f&r valves on the 3 rads when they are the...
hi guys
got a 4 year old persimmons new build with a baxi 50ff and megaflo cylinder piped on a s plan. custard foned me saying that 3 rads were getting hot but now are not. standard pipework to the rads ie plastic 10mm behind dry lining to a patress behind rads then elbows across to valves. now...
yer, thanks for the replies.
some of the answers are:
no cycling of boiler, no fan, ignition sequence, etc, no "click" of the diverter valve no nothing!
the cold water inlet filter is not blocked and i have 19mb of gas at the boiler.