Search results

  1. S

    scrap copper and brass

    round crawley way its 1800 a ton for off cuts soldered elbows and cylinders etc
  2. S

    gas training courses

    do the tilng course, i went that route and am doing full bathrooms now so most jobs i do im doing the whole sherbang and im guarenteed about 3 weeks work at a time rather than a few hours a day as a plumber. you might think about a weeks plastering course, you dont have to be too good at it...
  3. S

    Hairline crack in resin sink

    you could get it re enamellled but it would probly cost between £60 and a £100 depending on the crack. or you could do it yourseld witha kit http://www.tubbyuk.com/enamel_bath_repair_kits.htm
  4. S

    bevelled edging strip for kitchen worktop

    Hi All, Ive been asked to build a worktop in a kitchen to act as a breakfast bar. It is to attached to the end of a straight run of existing worktop at an angle of 45 degrees so the bend kicks out into the kitchen so i can have 2 seats on the outside and 1 on the inside. the problem i...
  5. S

    Large towels warmers and underfloor heating - help?

    the devi mat is electric right? in which case the thermocouple is located in one of the loops of the matting taking the temp of the floor so you should be ok with temp regulation. Theres an awful lot of adhesive and tiles down over it to protect it from temp fluctuations towel warmers and...
  6. S

    cooker hood

    thanks JJ,
  7. S

    cooker hood

    Hi I have a cooker hood/ extractor which simply recycles the air around the kitchen and id like to drill a hole in the wall and send the cremated burger smells outside. Anyone have an idea of anything i should be aware of before i drill a big hole in the wall and where i can get a vent pipe...
  8. S

    all in one shower units

    have you considered a "wet room" or am i way off the mark? Essentially a wet room is a waterproofed (tanked) room usually equipped with a walk in shower. The room itself becomes the shower enclosure, with a drain inset into a gently slopped floor in place of a conventional shower tray so...
  9. S

    pump rating for showers

    if youre putting the pump in the loft, make sure you have sufficient head to activate the flow switches or choose a negative head pump. The last stuart tuner monsoon pump i installed was 3 bar and served 2 bathrooms with pretty good pressure for both showers.
  10. S

    Can I replace a Single Rad with 2 series?

    if you put them in series, i.e join them together in the middle, you wouldnt be able to turn them on and off independently. if you turn one rad valve off you will be stopping the flow of water to both.
  11. S

    shower pump

    i agree, theyre probly the most expensive on the market.... buy cheap buy twice
  12. S

    replacing hot water cylinder

    last one i did was a right b!tch. took me 2 days lots of tarting about...really tight airing cupboard only just fitted in there,took ages to drain and i had to take the door off to get it, i swear the house was built around it.! and the cold feed was right at the back. £400 for the labour...
  13. S

    Shower / Pump advice

    id agree with johnD, but to give you a wider view you could go down the route of an unvented cylinder heated by your boiler but delivered via mains pressure. its a bit like the cylinder you have, but without a vent and instead of having the cold supplied to it from the loft, its mains fed...
  14. S

    showerpump/hot tank

    1050 high by 450 wide is about 120 litres Ive read other posts that suggest about 50 litres of hot per person. so something larger that you have would be an improvement a 2 bar pump should do you, ideally situated next to the hot water cylinder.
  15. S

    Cutting tap hole in a Franke fragranite sink

    get yourself a set of these. 50 sheets of your hard earned http://www.buybrandtools.com/acatalog/365-Drills-Porcelain-Tiles.html porcelain is 20 times harder than granite. youll only get about 10 holes out of each drill, but cheaper than the diamond crown jobbies from marcrist.
  16. S

    Shower Pump on Shared Cold Supply

    The valve would not technically be on the input side of the pump. Header >>>>>> tee to pump >>>>>>> check valve >>>>> ensuite the tee feeds the input to the pump and currenly when the pump is used it drains the ensuite pipework. opening a tap in the ensuite causes a pressure drop...
  17. S

    Shower Pump on Shared Cold Supply

    electronicsuk has the idea correct. header tank to ensuite serves wc, basing and bog in 22mm ive teed into this to supply the cold side of the pump the supply then continues into the ensuite. the pump has a separate hot and cold supply and the hot comes from the hwsv. so ive got...
  18. S

    Shower Pump on Shared Cold Supply

    Thats an interesting idea, but would it work? Would the pressure remain the same if the pump was before the check valve and the ensuite supply was after it? At the moment i thing that when the pump is on its sucking (impelling) the water out of the ensuite taps along with the water from the...
  19. S

    Shower Pump on Shared Cold Supply

    thanks, i'll cap off the cold after the tee to the ensuite then and take a separate cold from the mains instead. thanks for the quick response.
  20. S

    Shower Pump on Shared Cold Supply

    Hi All Ive just installed a techflow turbo 3 pump in a bathroom. The hot supply is a dedicated connection from a tech flange ( i like that word... flange) and the cold is from a separate connection from the cold cistern in the loft, although this connection is supplying the ensuite...
Back