  1. W

    ferrolli domicompact

    is the gas definately turned on???
  2. W

    gasfitter screwed me over.....

    looks like he's used a water isolation valve instead of a gas cock.
  3. W

    Viessmann or Worcester ?

    Just a note on viessmann custard services. I got one of the first vitodens in the country and ended up having every problem they became infamous for. Viessmann came and repaired it everytime without fuss even though it was more than 4 years old. After they updated their boiler to the current...
  4. W

    Viessmann or Worcester ?

    viessmann have fixed the reliability problems
  5. W

    IDEAL Icos M8020 Trombone

    I don't think ideal engineers recalibrate them, I'm sure they just replace the valve. Sham???
  6. W

    IDEAL Icos M8020 Trombone

    yup, nailed it.
  7. W

    Boiler Scrappage Scheme?

    during the blah blah blah he mentioned about how many people had benefited from the warmfront scheme (obviously not the ones who got shafted with the eyesore) Does this mean there's going to be a limited amount of "government appointed" installers allowed to install under the scheme? I bet it's...
  8. W

    Please, please, please help!

    leaning towards dhw thermistor
  9. W

    Modena 102 pump wiring harness

    Kevins advice is good but I'd like to point out the puddle of shyte you'll be in as a landlord if something goes wrong!! Messing with a gas appliance?????Pyjamas with arrows on for you!!
  10. W

    vokera boiler, no heat upstairs ,fine downstairs

    it would appear to be the case. Like glasgaegas said then, sounds like a system problem.
  11. W

    Britony SE80 - Error Code 60 (Flame Lock out)

    definately pcb for the 60. as kev said no flame detection for the 70-80, can be a by-product of a faulty pcb but you won't know til the board's changed. In my experience it's never been anything additional.
  12. W

    vokera boiler, no heat upstairs ,fine downstairs

    addendum. you'll find that the old stuffing box (part no 6919) won't want to come ot of the housing so you'll end up buying a front section (part no 2904) as well. If the hot water delivery is poor it could be that the actuator spring inside has dissolved and you need a new actuator (part no...
  13. W

    vokera boiler, no heat upstairs ,fine downstairs

    It's an electronic actuator on the left hand side. It clips onto the water section of the diverter valve. The stuffing box on the water side that stops water leaking through the pin has a tendancy to wear after a while and allow a small leak. This often results in the pin getting crudded up and...
  14. W

    Britony SE80 - Error Code 60 (Flame Lock out)

    Only the 60 light on (and be sure) 100% pcb.
  15. W

    Ravenheat rsf100et boiler

    really common problem on these is the primary thermistor. Your symptoms point to it.
  16. W

    What is this pump doing?

    it's keeping hot water circulating between the taps and the store. It's really designed for use if your taps are far away from the store and you're on a meter so you don't waste too much water. Should be on a timer to coincide with peak usage time.
  17. W

    vaillant turbomax vuw 242/1 combi boiler

    might be worth checking someone hasn't thrown some shoes in the understairs cupboard and knocked the gas off!
  18. W

    Covering over a internal gas pipe

    Then disregard my comments. :D Up where we live mole it's more known as dot and dab than dry lining.
  19. W

    Covering over a internal gas pipe

    He didn't specify that. I think he was suggesting what he might have thought would be acceptable. If I was converting my garage to a study dry lining it would be far cheaper and less intensive. I was just chucking him the options.