    Help with Worcester Highflow 3.5

    sounds very much like the diverter valve stucked in mid position.
  2. W

    Ariston Clas HE30 Condensing Boiler

    Have you got a mixer shower? If you have, it could be introducing cold water into the hot water supply whilst running water. If this is the case you would find that the shower will be able to get the same hot water as downstairs.
  3. W

    Ideal Isar M30100 - Backfiring

    small white pipe goes from the combustion chamber to the gas valve. If you take it off and find water in it (just a couple of drops) then there's your problem. Caused by one of three things, 1, condensate pipe restricted or blocked. That boiler will produce 2 litres of condensation per hour in...
  4. W

    Where to find an obsolete BAXI part?

    A balanced flue appliance is room sealed and therefore will have seals. It is not possible to do a spillage test on a room sealed appliance. It scares the bejeebers out of me that someone who is posting here is actually a registered fitter!
  5. W

    Honeywell CM67 relay switching noise

    I have the same problem. I've got 11 cm67's and the switching is noisy, especially at night.
  6. W

    Vokera Excell SP80 - High pitch squealing noise

    Common problem in our area. When the dhw is shut off the fulcrum arm returns but because you've had a very slight leak (not enough to show) on the front seal of the primary side, you don't get full return of the afore mentioned bobbin. The result is that squealing sound. Simply a case of giving...
  7. W

    Potterton Puma 80e - DHW causes lockout after 2 - 4 minutes

    I don't suppose you have the chemical symbol for jizzm do you Chris? I can't find it anywhere on the internet. I looked but all I came across (oo-err missus) were sites that wanted to charge me a fortune for pumping jizzm into a bucket (one of the buckets was called Angela, she was from Russia...
  8. W

    Vokera Linea 24 no CH but have HW

    I concede the point that the actuator is OK because it does push in CO mode. It is early morning you know!!! I've just got out of bed!!
  9. W

    Vokera Linea 24 no CH but have HW

    mark, forget the combustion analysis mode button it's telling you nowt and leading you down the path. It's an engineer function and thats all. As tony's said, put the boiler into ch mode and test for 240vAC on the actuator. If you have 240v your actuators gone if you haven't it's your PCB. If...
  10. W

    external gas pipes

    Yes it is acceptable to have the gas pipe exposed to the elements. The only unacceptable part is having the pipe work touch any masonry. It should be clipped to the wall but not touching the wall.
  11. W

    valor dream

    anyone got the coal layout for the first valor dream in pdf? eyethankyoo.
  12. W

    Vaillant combicompact vcw 242e

    The dhw t/stat is actually more of a throttle on the front of the water section, is this the one you're adjusting? As Danny said the dial on the fascia won't alter dhw temp, only ch temp. The dhw ntc is on the dhw pipe coming away from the dhw heat ex, it's piggybacked to the main ntc.
  13. W

    vokera 80 sp excell

    Not if it's the double allen key version!
  14. W

    Selling 2nd Hand gas appliances - regs?

    3 of us all posting at once!! That's service!
  15. W

    Selling 2nd Hand gas appliances - regs?

    I don't know about the selling of but corgis official stance on the fitting of second hand is, it's ok if the appliance is sound and has user and installation instructions with it. I can't see selling being legislated for because new appliance sellers needn't be registered.
  16. W

    Hey Danny.............

    ...........update on the compact please.
  17. W

    Heating On When Not Required?

    It's your dhw microswitch that's knackered, common problem on the eco's. The new one comes with a wiring harness attached so it's better to get a corgi repair engineer to do. The part number is 248207.
  18. W

    Vokera Linea 24 code 3

    The fan may well have been the problem but if your plumber replaced the silicone tubes wrongly after changing the fan then you'll still get a 03 code. could be worth swapping them round and giving it a try.
  19. W

    Vokera linea 28 domestic hot water problem

    Like the new thermistor you've put on your boiler when it's your plate heat exchanger that's fouled?