    Worcester 28i Junior Combi smells while running

    I presume the condensate pipe is after the trap of the bath down stream thus preventing the fumes coming back up the drain??? You will always get a few PPM CO from combustion, sure worcester say upto 100 ppm is ok.
  2. S

    how to take a Flamingo off the wall

    Failing that, just get the big hammer out!!! :lol:
  3. S

    Opinions on Ideal ISAR 24HE from Warmfront please...

    The new Isar's are defo better than the old ones. I would however always have a maintenance contract with ideal making sure it is properly serviced and not just performance tested every year. Divertors are prone to failing, as are the PCB's. I would put a couple hundred pounds the...
  4. S

    Glow worm 30ci combi boiler. Help PLEASE!

    its not so much of a tap as a blue round tube like thing. middle of the boiler towards the front just after the white plastic casing of the pcb. Remeber to turn the correct way when tring to loosen it.
  5. S

    failed pump

    Depends on how much heat can get away through gravity circulation but 5 mins is a bit longer than one would imagine. 2 mins maybe.
  6. S

    landlords safety cert?

    Cant see why not...as if something goes wrong and you are found to have been incompetant...you are still going to the clink!
  7. S

    BAXI COMBI 80 ECO

    Divertor valve passing and allowing the heated water that is ment to be heating the HW heat exchanger to go into your rads.
  8. S

    creating a vacuum - bunging feed and expanison tank

    Always use bungs..... cone type and expanding ones.... I NEVER drain anything....also I never relieve the pressure using the drain...always use the coupling of what I want to change..... for 3 ports I close a pump valve and that makes it into only 2 open ends. IMHO they are better than 95% I...
  9. S

    dodgy installation

    How about a riddor for leaving an AR situ??
  10. S

    Suprima 60 Boiler Hot water problems

    Boiler will only fire for short periods on HW mode....if its ok on heating then the boiler aint your problem. You could have a faulty motorised valve, faulty cylinder stat or a blockage in your HW circuit.
  11. S

    worc c1 / 28si emission problem

    How long is the Flue?? Restirctor as suggested and then possibly a fan, Have seen them become lazy on long flues.
  12. S

    The customer said he has gone off unvented hot water systems

    I think it is a small minority that fail, of the thousands I have seen and replaced or recharged I could count maybe 2 or 3 that have started to leak. It would be unfair to say that anything is 100% reliable and there will always be floods, how main rads pinholing have brought ceilings...
  13. S

    Volkera Excell 80SP hot water probs.

    Hot water diapramn, the divertor bobin or the HW micro switch are the likely culprits.
  14. S

    Room Thermostat v Valve Thermostats

    If the system is designed properly, the rads are sized to the room thus heating them up to the required temp at the same time as the hallway with the room stat is heated to 20oC
  15. S

    Room Thermostat v Valve Thermostats

    Easy......no stat.....boiler runs ans runs for full time timer is on.....cycling on and off...pump running const. Room stat...on for 1 hr maybe...up to temp...everthing shuts off...no energy used after this point until stat calls again.
  16. S

    creating a vacuum - bunging feed and expanison tank

    You can have 2 open ends and no need to release the pressure if you are careful. you should not even need to bund it if you are taking a rad off.
  17. S

    Room Thermostat v Valve Thermostats

    average saving for having an additional room stat is £65 per year approx, now as gas goes up so does the saving.
  18. S

    boilermate 2

    You could not see a motorised valve as this system does not use any! Sounds like possibly a couple of faults.....might have air in the system or a boiler stat fault. then there might be a control problem, Pump control board, room stat, timer?? Not sure if this tank switches on the CH pump...
  19. S

    Bosch 28i takes a long time to ignite

    Sounds indeed like a gas valve, but if you are an avid diy man this is NOT a job for you!!!! Need to be checked for tightness and set up afterward and a perfocmance check carried out.