    Potterton kingfisher

    They don't !!!??? Damn what have i been topping up all these years.......! :lol:
  2. P

    potterton puma 80e

    You can still get the main heat ex but to be honest i wouldn't spend any more on it as it will cost hundreds. New boiler time
  3. P

    Potterton Suprema 40

    Breaching the combustion chamber is illegal and dangerous......that constitutes stupid to me. As for you removing the overheat sensor.....that is a system safety device and if a gsr did that and left it so it would be riddor reportable! Regardless of the fact you were testing it it's stupid...
  4. P

    Baxi HE133 weird pressure loss.

    Check the obvious first.....leaks on system/rads. Then check the prv outlet pipe to see if it's dripping. May just need replacing the prv or the exp vessel charging rather than replacing
  5. P

    Baxi DuoTec Combi HE 28 - explosive ignition

    Part no 72003100. New style electrodes
  6. P

    potterton promax he

    Post again in the CC and we can help
  7. P

    Baxi 105e fluctuating DHW temperature

    If you know what your doing you could strip it out and clean it but i would replace it AFTER you have sorted the cause out ie why has the primary blocked?? You may need the system cleaning/powerflushing or it will just happen again.......and again......etc etc
  8. P

    Baxi Combi 80e problem

    Probably diaphram split in pressure diff. Does the microswitch make on the front left side of the brass housing when you turn water on? If not replace Easy fix. Search other postings for how
  9. P

    Removed a corroded rad, now no heating but water is fine

    Airlocked? Maybe single pipe system so water needs to flow through the rad to maintain the flow throughout hse..... What boiler? Pic of cylinder and controls would be good to
  10. P

    Condensate drain to flat roof - right or wrong?

    Nothing wrong in terminating onto a flat roof is the area is sufficient to dilute the condense and it runs into plastic guttering
  11. P

    Baxi Maxflo Combi WM losing water through drain

    Not the pump. Expansion vessel not charged. Either pump it up to recharge it or the diaphram is split and it needs replacing. Or fit an external one on the return pipework if you have space
  12. P

    main 24 he flame fail

    Cyril has written an alphabet????! :lol:
  13. P

    Boiler repair quote seems a bit steep

    All 105 expansions are at the back......yup an external would be fine but maybe the OP asked for a like for like?? Who the hell cares what was quoted if the op accepts then it's ok.....none of us have seen the job so stop carping......the price is steep assuming all things being...
  14. P

    Boiler repair quote seems a bit steep

    I think you will find that replacing the expansion vessel will almost always entail removing the boiler off the wall.......and hence 600 inc vat is not dear.
  15. P

    Gas Fire not Igniting

    Make? Model?
  16. P

    Baxi Duo Tec frozen - ideas needed

    OP - The clue is in the error code.....low water pressure. Often 1 bar (cold) will not be enough to allow the system to operate. Fill to 1.5 bar cold......you won't have any more issues. This IS NOT a frost protection issue, nor a faulty thermistor.......
  17. P

    Megaflow over-full - need to reduce pressure

    The bubble inside the megaflo is to allow pottable hot water to expand. The external expansion vessell is for system water that is pumped around the boiler/rads/tank. It's this that needs a recharge.......use a foot pump and recharge it (drain system water first) if it holds job done, if not...
  18. P

    Baxi 80e & 105e

    Wasting your money my friend. The symptoms you describle are not ususally explained by a sticking pin or holed diaphram. Thermistor or plate heat ex is much more likely
  19. P

    Megaflow over-full - need to reduce pressure

    Perfectly safe to reduce the pressure via a rad bleed valve. As to why it has shot up it's possible the iso valve is letting by raising the water pressure or the expanssion vessel may have lost it's charge or may need replacing. Get a G3 competant engineer to check it over