  1. P

    Help, no hot water and pressure at zero everyday

    Fault has to be on primary side as the hot water expansion is internal on a megaflo and any fault would not drop the primary pressure. As stated the 3 most likely are.....expansion vessel needs a recharge or replacement, prv letting by due to above or on its own or a leak on the system
  2. P

    baxi insert 2 boiler

    Look pal we both know there are plenty on here that will 'have a go' once we have done the diagnostics. I am not saying this OP will but as we both know it almost certainly requires an rgi to fix legally why do you bother to point the way.... You are either showing off your knowledge, don't...
  3. P

    baxi insert 2 boiler

    You deal with it your way i'll do what i think is right.
  4. P

    baxi insert 2 boiler

    You need and rgi for this one i am afraid as unable to give out gas specific info. Try getting someone recommended
  5. P

    Potterton Suprima Gas Boiler Advice Needed!!

    The model details are behind a panel on the right hand side (where your control nob is. There will be a screw above this and possibly one on top too......undo and slide the whole panel towards you. Details underneath
  6. P

    Potterton suprima

    But surely this would cause overheat trips. This is a solid lump of cast iron....where does the latent heat go if you wire as above???
  7. P

    Megaflow CL170 - Cold water warm

    Mixer tap letting by or possible hot and cold pipes very close and your getting heat transferance......doubt that one tho. Does it happen out of every cold tap or just one?
  8. P

    Baxi Potterton boiler Suprima 40L: pilot light not igniting

    You need a good rgi who can diagnose faults. This is most likely an issue requiring entrance to the combustion bxx and as such needs a qualified rgi. Sorry can't help any further
  9. P

    Boiler Overheating on cool down.

    Possibly air but you say its overheat so i would guess your bypass is shut too much if manual (gatevalve) or too short a run or auto bypass isn't working. Never keen on selectric pumps. Come across many which slow too quickly and cause over heat.
  10. P

    Potterton Puma 80 shutting off after running hot water?

    Boiler stat? Heat exchanger scaled?
  11. P

    Baxi 80e or 105e 'pump or low pressure' problem

    try bleeding the pump. If not diverter maybe sticking.....fixed price repair?
  12. P

    BAXI Combi Instant 80 HE problem

    Diaphram split in hw differential. replace
  13. P

    POTTERTON PERFORMA 24 ECO HE problem

    You have not told us if the fan spins?? Does it? Could be aps, fan or board
  14. P

    Baxi Combi 105 HE leak

    Just turn the power off and turn off all 3!!! If your this bad with the water supply i feel a 10 page posting coming
  15. P

    baxi 105e problems

    If it isn't a blockage or pump issue then you will ned to replace the diverter section (where the pump switch proves.) I would suggest you replace the whole section
  16. P

    Help !!! 1 cold radiator

    Mechanize - your is a balancing issue look on faq's
  17. P

    Conduit for new gas supply

    Not sure you should be touching this. If existing supply you are in breach of regs and if fitting for a new supply you need to follow regs ie depth, materials, protection..... Not for amateurs so can't help you. sorry
  18. P

    Combi 80 Boiler stop/start ??

    Thermistor? Pump? Board?
  19. P

    Reposition Megaflo isolating valve / strainer or not ????

    I would keep it simple and fit a new stopcock on the cold supply before the combivalve and after the T from the mains to the rest of the house....Tchnically the valve needs to be accessible for servicing but thats the installers for you!