  1. P

    Conduit for new gas supply

    Why not ask the installer or transco?? What is the gas supply for and what is it coming from and connecting to?
  2. P

    potterton suprima50 new pcb

    Did you wire up the new board correctly?? Sounds as if it's external ie port valve or thermostat. It maybe a duff board......where did you get it from??
  3. P

    Baxi Barcelona

    Right direction........call out a good rgi repairer
  4. P

    Help !!! 1 cold radiator

    try turning off all other rads and see if the pump pushes through to it. Check it's been piped correctly to
  5. P

    Can you ID these pipes ? ( make and probably use ? )

    Water carring barrier pipe. Hep John Guest etc etc Yes they can be used for potable water or heating systems
  6. P

    need a quote

    between 1 and a billion But guess around 1200 to 2000
  7. P

    potterton suprima 40 / 50 boiler banging weezing

    If your missing the seal then i would stop using the boiler!!!! It's white and is attached to the case not the boiler and runs all around the outside......doh
  8. P

    Pressue drop!!!

    Happens to lots of baxi's Unless the pressure drop is permanent don't worry about it
  9. P

    Baxi 80 eco - Apparent sludge Problem

    Lots......get someone who knows what they are doing in! Is it on hot water or on heating or both? At worst both heat ex's can be changed at best a powerflush may do the job depending on what you say. That said its not the worlds best boiler and pretty old......if you have to spend more...
  10. P

    Baxi solo 15HE air lock problem

    Most heat only fits include a drain cock on pipework just above the boiler.......try backfilling system with hose connected to a tap be careful not to overfill !
  11. P

    Opinon / Advice wanted on Install

    These days most manufacturers will allow a plugged boiler if it goes into an unswitched socket and from the pic i believe it is unswitched. Others have covered the other points you raised
  12. P

    Baxi Duo-tec HE boiler fault. E133

    Trust us......90+% electrode issue.......RGI required
  13. P

    How to replace thermistor on Suprima 80 HE

    You are so masterful rob lol
  14. P

    Is this a Gas tap ?

    Don't bother....poster is a muppet. Wind up.
  15. P

    Checking a quote

    Can't comment on cost as has been said we haven't seen the job......just a couple of queries tho....has your inlet mains been checked for pressure and flow rates, standing and dynamic?? Even a megaflo would struggle to fill 2 baths at the same time as well as run hot water elsewhere if these are...
  16. P

    Potterton Suprima firing up and shutting off immediately...

    What happened to no gas specific details being offered on here??? All the above suggestions bar a few require combustion box off.......sometimes we are our own worst enemies. edit. rereading some i can see references to getting an rgi in but i still think you are being too specific with...
  17. P

    Expansion Vessel Replacement - is it easy?

    G3 installations need to be serviced annually by a G3 certified engineer. These things can be bombs if not maintained/installed correctly.
  18. P

    Baxi instant 105e combit boiler automatic vent

    Auto air vent should be left open by a half/1 turn. kettling may not be associated with air in system. Could be other causes
  19. P

    baxi instant combi 105e no hot water

    20 mins???!! Wishful thinking
  20. P

    problem with baxi 105 he boiler - flashing red light on 60

    The pump is airlocked. Undo the screw in the centre and bleed the pump and make sure the auto airvent nipple is open