Search results

  1. P

    potterton 80e "no power light"

    Please do all the heateam engineers a favour and get a new one :lol:
  2. P

    Puma cutting out

    Unfortunately sometimes you need to replace the diverter section not just the wax capsule. They are dammed hard to get off too if the back nut won't come off easy......doubt it's the pump.....you would get thermal transfer into the flow pipe at least a little way.
  3. P

    Try Ons........Last Man On the Job carrys The Can

    A few years back i was called out by a bloke who said his immersion wasn't working. Got there and was shown upstairs to airing cupboard. All doors closed and quite dark. Asked for landing light to be switched on and he said the bulb had gone. Did my electrical safety and isolated. Just as...
  4. P

    Boiler not firing

    Doh.....he knew that already......thats why he came on here and asked.....lol Is it just me or are more and more try on's asking for help/confirmation/fishing,on gas/safety specific info on this forum? His 'i'll let you know how i get on' comment says it all. :cry:
  5. P

    Baxi Duo-tec Combi HE - Alarm Light / Thermastat

    Nope. Change the batteries first. Follow instructions on how to get the transmitter and reciever to talk to each other. If this doesn't work only then replace the unit. It may be covered under your warranty. Check this after you replace the batteries
  6. P

    Heateam warning notice

    He's a Troll. Leave him to his fantasies. He can't substantiate so let's not give him the oxygen of a response.
  7. P

    Heateam warning notice

    Yawn.......finished? Hope so 'cause talking that much rubbish must mean a frustrated DIYer. I presume you can point us in the direction of the statistics of where you obtained this drivel?......no thought not.
  8. P

    Heateam warning notice

    So speaks Jackpike.......an expert in drivel...... A flue not properly supported is AR ie at risk.....your installer should have fitted it TO regs and MI's no excuses Same for prv even tho it's ncs Finally, like all insurances if you give em room to wriggle.....so get it fixed and enjoy...
  9. P

    diagnostic please.

    It could be any one of a number of issues but as this is an open flued appliance and therefore more likely to be dangerous if not maintained or fited properly i strongly recomend you get an rgi who knows what they are doing. As an aside 70 quid to service fire and backboiler seems a touch...
  10. P

    Neighbour requesting I move boiler vent installed pre 2002..

    Perhaps you did but i would have marked the offer 'without predjudice' in case you need to withdraw said offer (bargaining chip)
  11. P

    Potterton Promax HE Plus

    Technical says check fan, gas valve resistance and if ok then pcb. In my experience, change the pcb
  12. P

    potterton suprima 60 driving me potty!!!!!

    Not if it is already the 'new style'. Molex connectors only
  13. P

    Potterton Performa 28i fault

    Check the ch microswitch is making. It has 2 red wires going to a black oblong switch and is in the lower right hand side. Held with a circ clip. Remove it and with a small screw driver push it into the inside. A microswitch should make and fire the boiler. If not a new wiring harness is...
  14. P

    Baxi ecogen boiler

    From what i hear from the testing/trialing period they have shown a lot of promise. BG and Calor to roll out in september.
  15. P

    Business people

    Mountainwalker. You have obviously not read my post. I am talking about GAS specifically. I work in a closed shop. I for one have paid huge amounts to be registered. I fail to see the benefit of helping diyers carry out what amounts to work i and others should be getting paid for. That...
  16. P

    Business people

    Tony, I am aware that forum rules preclude gas work related advice. I just think we as a forum are too quick with 'it's a fan or aps issue'. Whilst no advice on changing may have been given it's a high probability that as this is a DIY site then the OP is going to 'have a go'. As i...
  17. P

    Business people

    Hmmm, Just seen this thread. Won't comment on the plumber side but i have to agree with the original OP. I have seen posts from gas qualified lads giving out what amounts to gas related answers or as near as dammit. We work in a closed industry. We have all paid out (and continue to)...
  18. P

    another baxi 105e leak

    Correct. I belive you can use the diaphram repair kit (contains the tiny O ring). Be warned tho they are a swine to strip. Perhaps replacing the back section will be easier. It is available as a single part
  19. P

    No hot water except when heating on

    Most heat only boilers are 'dumb'. If your boiler fires on heating but not hot water then 99% of the time it's external. Just change the port valve.......40 minute job including drain down. Simples
  20. P

    poxi bahama 100!! not starting/firing

    Cheers Rob........got out of hospital last week......kidney stones. Never new you could have that much pain......morphine is good tho lol....now just need the name of a good local supplier....... :lol:
Back