  1. P

    Hepvo valve

    Why do you need to know? Just so i can put the answer into context
  2. P

    Gas flue - noise - draught

    A pic or too would help of the termination plus make/model of fire before i can comment
  3. P

    Baxi Duotec combi boiler - hot water problem

    Usually replacing the cartridge in the diverter valve sorts it (depends on whether you have integral bypass via plate heat ex or bypass pipe tho) if not you need to change the whole div valve. Could be blocked plate heat ex or the div valve motor head also but my money is on the DV
  4. P

    poxi bahama 100!! not starting/firing

    Manufactured for 3 yrs was 3 too many.......i hate repairing these things. I groan when i get sent to one........ :cry: As for fitting it second hand and it don't work.......oh dear. Another illegal install........
  5. P

    HOt water problem with Baxi Combi

    ok.......does the pin on the front diferential come out and make contact with the micro switch when you open a tap?......front bottom left. If it doesnt your diaphram has split and needs replacing. Does your flow pipe for heating warm up when you call for water? If so it is the diverter...
  6. P

    how to mend cut in lead pipe?

    Leadlok or a philmac universal connector. You will need to turn offthe supply in the street as you would need to cut through the pipe to fit either of these. Be careful just bending and hammering.....if it fails you won't have enough straight pipe to fit connectors to and you will need to go...
  7. P

    Upgrading pipe between stopcock and thermal store

    As has been said.....your flow rate is defined by the smallest bore of your run.....i doubt you will see any significant impovement by upgrading the internal 15mm. You ned a 25mm mdpe run then 22mm from stoptap
  8. P

    HOt water problem with Baxi Combi

    Hang on i will check the crystal ball........ Sorry OP but without at least the model name/number it's a shot in the dark. Post more details
  9. P

    baxi he80 fan flu fault

    And you have checked the aps?? Nope thought not. It MIGHT be the pcb......but unless you know what your testing for your likely to throw away £100+......
  10. P

    baxi he80 fan flu fault

    Fan or aps. You need an rgi for this i am afraid.
  11. P

    potterton suprima 80

    Unfortunately there are thousands more like him fleecing the public and tarring us with the same brush :cry:
  12. P

    Powermax 155X Reduced Hot water Flow.

    If it's just one tap it is the tap thats faulty not the boiler. Otherwise, mixervalve or blockage
  13. P

    brand new main 24 he not working

    Sorry but i smell a rat here. My guess is this is an illegal install. OP call heateam but they will require serial and date of install plus installers Gasafe registration......and if it is an install issue they will bill you.
  14. P

    potterton suprima 80

    I too have never seen a post off you in the CC but will happily be corrected by you if i am wrong. You surely must see that your basic knowledge is so poor as to bring into question your competance to be doing plumbing work let alone gas work........(apologies to all qualified plumbers). If...
  15. P

    Different Suprima Fault

    Your boiler is fine....the problem is external. 2/3 port valve is mu guess. And the suprima is a good boiler......pcb aside. New boards much more robust
  16. P

    Where's my black grit coming from?

    Most black 'grit' is the sloughing off of aluminium deposits from the inside of ali heat exchangers. Not seen this as much if at all on stainless. It should be flushed out on your first service and isn't a problem unless it's a massive amount. PLASTIC should be used for condense runs
  17. P

    Re-fit toilet in concrete floor

    True. Just be careful. If it cracks then you can get fernco adaptors but you would need to dig out around it to attach......or if the floors coming up replace the lot
  18. P

    Baxi 80e, h/w alternates between hot/cold - H/E or diverter?

    700!! If when you call for hw your flow pipe on the rads side starts to heat up then it's the diverter valve. If it doesn't and the boiler cycles on off constantly then it's likely to be a sludged/scaled plate heat ex If i changed both (about 150) then it's an hours work, maybe 2 if...
  19. P

    help needed noise in pipes then boiler shuts down and water

    Why gate valves? unless someone has touched em the boiler worked before. Try Pump.....working? Gate valves....are they open why needed. Finally, system blockage. Just how dirty is the system? My guess would be on the pump being seized or dead
  20. P

    Re-fit toilet in concrete floor

    Older toilets like this were 'set' on top of a concrete mix then damped down onto it to level then dry. My guess is that you will crack the toilet if you try to break it out. Even if you manage it there will be a plug of concrete adhered to the underside...... I would suggest you try...