    Ho Ho Flippin Ho obviously Santa hasn't had heating problems

    if you turn all the working rads off does it make any difference
  2. F

    Potterton Puma 80e

    it would help if you checked the burner pressure or gas rate. the burner may not be full on.
  3. F

    Flueless gas fires.

    the life of the catalytic converter is only 8 months if used continuosly just about the lenght of our winters or you could leave it and not use it,take your choice.
  4. F

    Fluless Gas Fires

    you won't find one corgi who will fit them in their own house or any relatives house mother in law excluded.
  5. F

    Myson Apollo 80 si Pilot light will not relight

    you need a new thermocouple
  6. F

    Burner and pilot go out together

    the overheat stat is operating to shut pilot off the thermostat needs recalibrating this can be done with a small screw driver find the hole with + and - on the underside of the ranco stat.
  7. F

    Ariston Micro Genus 27 Blowing fuses

    i have uploaded the service manual here http://www.megaupload.com/?d=CIFKWGF0
  8. F

    Corgi report on Flueless Gas fire incident

    most accidents are caused by human error as in this case but it would seem the manufacturers instructions were also at fault. One question that will no doubt be asked is “why did the atmosphere sensing device (ASD) not operate and cut the appliance off sooner?” This is something that CORGI...
  9. F

    One pipe system + new boiler

    i can tell u B.G. quoted four grand for the job and were happy to take the dosh.
  10. F

    One pipe system + new boiler

    Installed one last week it works perfectly although only small house so the pipe run wasn't to long. dosnt need a bypass valve. it doe's require a large amount of flushing. make sure none of the radiators run off the 1inch pipework and have it removed.
  11. F

    myson apollo

    check pump
  12. F

    Worcester 240 Combi Boiler Installed 1992 New.

    i would suggest when the main burner is ignited that the draught caused by the main flame draws the pilot flame away from the thermocouple thus cooling it. try repositioning the thermocouple.
  13. F

    Gas can be dangerous

    The fire would seem to have been the main source of heating for the house which i would say is a misuse of the fire as they are only intended for decorative effect.I wonder if this was explained at the point of purchase.They look good but when i have informed customers of the disadvantages...
  14. F

    Replacing Gas Fire with Back Boiler

    i would get 3 quotes and leave the purchase to the installer unless he dosn't object. always go with 28 kw for the extra hot water flow rate. try and locate in kitchen less expensive.
  15. F

    Is my plumber ripping me off?

    what skill is involved in fitting a leadlock and how many years does it take to learn. why did two turn up when you had already done the labouring.
  16. F

    Vokera Excel

    about 20 quid. who's doing the repair you or the landlord?
  17. F

    Vokera Excel

    you can download the manual here go to installer discontiued products hope this helps http://www.vokera.co.uk/
  18. F

    ariston microgenus 23 repeated shutdowns

    are you saying the boiler locks out and you have to reset using reset button or that the burner will light then go out completely and the relight?
  19. F

    ariston combi water too hot

    Have fixed the boiler now. The problem was that the burner was not modulating and leading to the water being heated to rapidly with no chance for the thermistor to react and control dhw. On return i rechecked burner pressures high and low,there was no flame on the low setting with the leads to...
  20. F

    ariston combi water too hot

    i have been called out to an ariston micro genus with same problem. the hot water comes out about 80C at which point the burner shuts down,when water cools down burner will relight. The dhw thermostat will not control the water output temp. I swapped the thermistors around and the fault...